Banner LTF Series Скачать руководство пользователя страница 5

© Banner Engineering Corp. www.bannerengineering.com

5

B

ANNER

 E

NGINEERING

 C

ORP

 LTF T

IME

 

OF

 F

LIGHT

 L

ASER

 D

ISTANCE

 S

ENSOR

 Q

UICK

 S

TART

 G

UIDE

Figure 8: 

Sensor Menu Map

Run

Mode

Enter Quick Menu Loop

(see Quick Menu diagram)

MENU A_OUT

MENU D_OUT

MENU INPUT

Enter

Top Menu

(Continued on right side)

(Continued from left)

Top Menu

MENU MEASURE

MENU DISPLAY

MENU INFO

MENU RESET

Sub Menus

Top Menu

Sub Menus

or

or

Go Back to Parent Menu

Select Menu Item

Press to Save Setting

Press and Hold to Go Back

to Run Mode

OffDly  0 ms

Off1Sho  0 ms

OnDly  0 ms

On1Sho  0 ms

A12000mm

00050mm

Tch4mA 50mm

Tch20mA 12000mm

Tch2Pt Tch20mA

Tch2Pt Tch4mA

W02000mm

Tch12mA 6000mm

TchMid Tch12mA

TchMid WndSize

Slope Negative

Slope Positive

LossSig 20.5 mA

LossSig Hold

LossSig 3.5 mA

TchSPt1 50mm

TchSPt2 12000mm

Tch2Pt TchSPt2

Tch2Pt TchSPt1

W00020mm

TchMdPt 6000mm

TchMid TchMdPt

Offset  0 mm

TchMid Offset

TchMid WndSize

Mode Health

Mode Alarm

Timer On1Sho

Timer OffDly

Polarity NPN

Polarity PNP

Mode Swtch

Mode Swtch

Mode Wnd

Mode Wnd

Active High

Active Low

Type LasrEnbl

Type Teach

Type Trigger

Type SyncMstr

Type SyncSlve

Type Disabled

Trigger Average

Trigger Sample

Speed Standard

Speed Fast

Speed Medium

Speed Slow

Trigger Max

Trigger Min

Trigger Range

Trigger TrackMax

Trigger TrackMin

Timer Off1Sho

Timer OnDly

A12000mm

A00050mm

Sleep 1min

Sleep Disabled

Units in

Units mm

View Invert

View Normal

Sleep 5min

Sleep 15min

Sleep 60min

Version 1.0.0

Model LTF12I

P/N 94849

S/N F..S..P..D..

A_OUT Adj4mA

A_OUT Adj20mA

A_OUT Tch2pt

A_OUT TchMid

A_OUT Slope

A_OUT LossSig

D_OUT Tch2Pt

D_OUT TchMid

D_OUT Mode

D_OUT Polarity

D_OUT Timer

INPUT Active

INPUT Type

MEASURE Trigger

MEASURE Speed

D_OUT AdjSPt1

D_OUT AdjSPt2

DISPLAY Sleep

DISPLAY Units

DISPLAY View

INFO Version

INFO Model

INFO P/N

INFO S/N

RESET No

RESET Yes

Zero Far

Zero Near

DISPLAY Zero

Shift Auto

Shift Off

DISPLAY Shift

Default Setting

Offset  0 mm

TchMid Offset

Shift TchZero

(in SPt mode only)

SPtRef Object

SPtRef Backgrnd

Offset 0 mm

(in SPtRef Custom
mode only)

SPtRef Custom

Hyst Auto

D_OUT Hyst

D_OUT SPtRef

D_OUT Offset

Содержание LTF Series

Страница 1: ...isplay Buttons and Icons Use the sensor buttons Down Up Enter and Escape to program the sensor and to access sensor information Figure 1 Features Three LED indicators provide an ongoing indication of...

Страница 2: ...n the Sensor Menu a checkmark in the lower right corner of the display indicates that pressing Enter accesses a submenu Press Enter to save changes New values flash rapidly and the sensor returns to t...

Страница 3: ...ch menu For TEACH options follow the TEACH instructions in the instruction manual In addition to programming the sensor use the remote input to disable the buttons for security preventing unauthorized...

Страница 4: ...gain to save the new value and return to the Quick Menu Press Cancel to ignore any changes made if only some digits have been changed Figure 7 Quick Menu Map Window Mode LTF Sensor Menu MENU Access th...

Страница 5: ...1Sho Timer OffDly Polarity NPN Polarity PNP Mode Swtch Mode Swtch Mode Wnd Mode Wnd Active High Active Low Type LasrEnbl Type Teach Type Trigger Type SyncMstr Type SyncSlve Type Disabled Trigger Avera...

Страница 6: ...els 2 5 k minimum load resistance Remote Input Allowable Input Voltage Range 0 to Vcc Active Low internal weak pullup sinking current High State 4 3 V at 740 A maximum Low State 1 3 V at 800 A maximum...

Страница 7: ...vercurrent Protection A Supply Wiring AWG Required Overcurrent Protection A 20 5 0 26 1 0 22 3 0 28 0 8 24 1 0 30 0 5 LTF12 Models Figure 9 Speed Slow 256 ms Figure 10 Speed Medium 32 ms Figure 11 Spe...

Страница 8: ...d by Banner Engineering Corp Any misuse abuse or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not i...

Страница 9: ...BANNER ENGINEERING CORP LTF TIME OF FLIGHT LASER DISTANCE SENSOR QUICK START GUIDE Document title LTF Time of Flight Laser Distance Quick Start Guide Part number 194136 Revision F Original Instruction...

Страница 10: ...ventory Delivery Lifecycle Information Banner Engineering LTF12IC2LD W 30 LTF12IC2LDQ LTF12IC2LD LTF12IC2LDQP LTF12UC2LD LTF12UC2LD W 30 LTF12UC2LDQ LTF12UC2LDQP LTF24IC2LD LTF24IC2LD W 30 LTF24IC2LDQ...