L-GAGE
®
LT7 Long-Range Time-of-Flight Sensor
P/N 120244
7
Banner Engineering Corp.
•
Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Main
Menu
Procedure
Example Displays
Result
QuickSet <ENTER>
• Press or to
scroll through Main menu
options
QuickSet
TEACH IN
OFFSET
UNIT
SERIAL
RS422
PASSWORD
FACTORY <PRESET>
• Sensor scrolls through Main menu options.
• See following steps for procedures if other than QuickSet
is selected.
• With QuickSet visible on the
display, press
QuickSet
<ENTER>
• Sensor enters QuickSet program.
• Press to teach current
condition to Output 1.
• Press to teach current
condition Output 2.
• 196 mm to target
• Output 1 OFF
• Output 2 ON
• Bars indicate a strong signal
• Current measured value is displayed on top line;
received energy value is indicated by bar graph (the more
bars, the stronger the received signal). Outputs Q1 and Q2
are indicated as ON or OFF by the LED status indicators
and by whether the “Q” is capitalized on the display (Q1 =
Output 1 ON; q1 = Output 1 OFF).
• Press
– or –
• Use
Escape
function*
• Sensor saves settings and returns to Main menu.
���
���
���
���
���
���
* Escape function available throughout Programming mode; returns sensor one step higher in menu.
Q1 Q2
q1
Q2
196