Class 2 Lasers
Class 2 lasers are lasers that emit visible radiation in the wavelength range from 400 nm to

700 nm, where eye protection is normally afforded by aversion responses, including the

blink reflex. This reaction may be expected to provide adequate protection under

reasonably foreseeable conditions of operation, including the use of optical instruments for

intrabeam viewing.

LASER LIGHT

DO NOT STARE INTO BEAM

CLASS 2 LASER PRODUCT

           Acc to IEC 60825-1:2007.

λ=640-670nm; P=0.45mW

PW: 45-1,750ms

Complies with 21 CFR 1040.10 and 1040.11

Except for deviations pursuant to laser notice

No. 50, Dated June 24, 2007.

Figure 1. FDA (CDRH) warning label (Class 2)

Class 2 Laser Safety Notes
Low-power lasers are, by definition, incapable of causing eye injury within the duration of a

blink (aversion response) of 0.25 seconds. They also must emit only visible wavelengths

(400 to 700 nm). Therefore, an ocular hazard may exist only if individuals overcome their

natural aversion to bright light and stare directly into the laser beam.

Class 1 Laser Models (LM80 Models)

Class 1 lasers are lasers that are safe under reasonably foreseeable conditions of

operation, including the use of optical instruments for intrabeam viewing.

Figure 2. FDA (CDRH) warning label (Class 1)

Laser wavelength: 655 nm

Output: < 0.33 mW

Pulse Duration: 45 µs to 1750 µs

Installation Instructions

Sensor Installation

Note: Handle the sensor with care during installation and operation. Sensor windows soiled by fingerprints,

dust, water, oil, etc. may create stray light that may degrade the peak performance of the sensor. Blow the

window clear using filtered, compressed air, then clean as necessary using 70% isopropyl alcohol and cotton

swabs or water and a soft cloth.

Install the Safety Label

The safety label must be installed on or near the LM sensors.

Note: Position the label on the cable or near the sensor in a location that has minimal chemical exposure.

Figure 3. Typical installation; other mounting options are possible.

1. Remove the protective cover from the adhesive on the label.
2. Wrap the label around the LM cable, as shown.
3. Press the two halves of the label together.

 

 