Banner L-GAGE LE250 IO-Link Скачать руководство пользователя страница 3

Incorrect

Correct

Figure 7. Orientation for a height difference

Incorrect

Correct

Figure 8. Orientation for a color or luster

difference

Sensor Mounting

1. If a bracket is needed, mount the sensor onto the bracket.
2. Mount the sensor (or the sensor and the bracket) to the machine or equipment at the desired location. Do not

tighten at this time.

3. Check the sensor alignment.
4. Tighten the screws to secure the sensor (or the sensor and the bracket) in the aligned position.

Wiring Diagrams

3

1

4
5

shield

2

+

12–30 V dc

D1_Out
D2_Out
Input

Load

NPN

PNP

* User-configurable PNP/NPN setting

Load

or

Figure 9. Dual Discrete Models

Key

2

3

4

1

5

1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray

Display

Figure 10. LE550 Display in Run Mode

The display is a 2-line, 8-character LCD. The main screen is

the Run mode screen, which shows the real-time distance

measurement.

Buttons

Use the sensor buttons DownUpEnter, and Escape to program the sensor and to access sensor information.

L-GAGE

®

 LE250/550 Dual Discrete Laser Sensors

 

 

P/N 185580 Rev. C

www.bannerengineering.com - Tel: +1-763-544-3164

3

Содержание L-GAGE LE250 IO-Link

Страница 1: ...ete Sensor Features Three LED indicators provide ongoing indication of the sensing status Power LED Indicator Solid Green Normal operation power On and laser On Flashing Green 1 Hz Power On and laser Off laser enable mode Discrete Output LED Indicators Solid Amber Discrete Output is On Off Discrete Output is Off Laser Description and Safety Information CAUTION Use of controls or adjustments or per...

Страница 2: ...PLIES WITH IEC 60825 1 2007 CLASS 1 LASER PRODUCT Output Complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice N o 50 dated June 24 200 7 Figure 3 FDA CDRH warning label Class 1 Laser wavelength 650 nm Output 0 22 mW Pulse Duration 150 µs to 900 µs Sensor Installation NOTE Handle the sensor with care during installation and operation Sensor windows soiled by finge...

Страница 3: ...d the bracket in the aligned position Wiring Diagrams 3 1 4 5 shield 2 12 30 V dc D1_Out D2_Out Input Load NPN PNP User configurable PNP NPN setting Load or Figure 9 Dual Discrete Models Key 2 3 4 1 5 1 Brown 2 White 3 Blue 4 Black 5 Gray Display Figure 10 LE550 Display in Run Mode The display is a 2 line 8 character LCD The main screen is the Run mode screen which shows the real time distance mea...

Страница 4: ...nges In the Sensor Menu a return arrow in the upper left corner of the display indicates that pressing Escape returns to the parent menu Press and hold Escape for 2 seconds to return to Run mode from any menu or remote teach Sensor Programming Program the sensor using the buttons on the sensor or the remote input limited programming options From Run mode use the buttons to access the Quick Menu an...

Страница 5: ...ress Enter to save the new value and return to the Quick Menu Quick Menu D1 SPt1 value Run Mode D1 SPt2 value D2 SPt1 value D2 SPt2 value Spt2 not available unless in Window Mode set value with or Save setting and return to Quick Menu Cancel and return to Quick Menu access Sensor Menu Top Menu Figure 12 Quick Menu Map Window Mode Sensor Menu MENU Access the Sensor Menu by pressing Enter from Run m...

Страница 6: ...Pt TchSPt2 Tch2Pt TchSPt1 WndSize 300 mm TchMdPt 500 mm TchMid TchMdPt TchMid WndSize Mode Health Mode Alarm Timer On1Sho Timer OffDly Polarity NPN Polarity PNP Mode SPt Mode SPt Mode Wnd Mode Wnd Active High Active Low Type LasrEnbl Type Teach Type SyncMstr Type SyncSlve Type Disabled Speed Standard Speed Fast Speed Medium Speed Slow Timer Off1Sho Timer OnDly AdjSPt2 1000 mm AdjSPt1 100 mm Sleep ...

Страница 7: ...x Low State 1 3 V at 1 6 mA max Measurement Output Rate Class 2 Laser Models 1 ms Class 1 Laser Models Fast 1 ms Class 1 Laser Models Std Medium Slow 2 ms Minimum Window Size LE250 1 mm 0 039 inches LE550 10 mm 0 39 inches Boresighting LE250 4 mm radius at 400 mm LE550 1 cm radius at 1 m Maximum Torque 2 N m 17 7 in lbs Indicators Power LED Indicator Solid Green Normal operation power On and laser...

Страница 8: ...nt protection may be provided with external fusing or via Current Limiting Class 2 Power Supply Supply wiring leads 24 AWG shall not be spliced For additional product support go to http www bannerengineering com Supply Wiring AWG Required Overcurrent Protection Amps 20 5 0 22 3 0 24 2 0 26 1 0 28 0 8 30 0 5 Performance Curves LE250 Dual Discrete Models LE550 Dual Discrete Models 0 6 0 5 0 4 0 3 0 ...

Страница 9: ...LUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGINEERING CORP B...

Отзывы: