Banner L-GAGE LE250 IO-Link Скачать руководство пользователя страница 1

Quick Start Guide

Laser displacement sensor with dual discrete (switched) outputs

This guide is designed to help you set up and install the L-GAGE

®

 LE Laser Gauging Sensor. For complete information on

programming, performance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at 

www.bannerengineering.com

. Search for p/n 185600 to view the manual. Use of this document assumes familiarity with

pertinent industry standards and practices.

WARNING: Not To Be Used for Personnel Protection

Never use this device as a sensing device for personnel protection. Doing so could lead to

serious injury or death. This device does not include the self-checking redundant circuitry necessary

to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an

energized or de-energized sensor output condition.

Features and Indicators

Power LED

Indicator

Analog Output

LED Indicator

Display

Discrete Output

LED Indicator

Push Buttons

Figure 1. LE Dual Discrete Sensor Features

Three LED indicators provide ongoing indication of the sensing

status.

Power LED Indicator

Solid Green = Normal operation, power On and laser On
Flashing Green (1 Hz) = Power On and laser Off (laser enable

mode)

Discrete Output LED Indicators

Solid Amber = Discrete Output is On
Off = Discrete Output is Off

Laser Description and Safety Information

CAUTION: Use of controls or adjustments or performance of procedures other than those specified

herein may result in hazardous radiation exposure. Do not attempt to disassemble this sensor for

repair. A defective unit must be returned to the manufacturer.

Class 2 Laser Models

CAUTION: Never stare directly into the sensor lens. Laser light can damage your eyes. Avoid

placing any mirror-like object in the beam. Never use a mirror as a retroreflective target.

For Safe Laser Use - Class 2 Lasers

Do not stare at the laser.

Do not point the laser at a person’s eye.

Mount open laser beam paths either above or below eye level, where practical.

Terminate the beam emitted by the laser product at the end of its useful path.

Reference IEC 60825-1:2007, Section 8.2.

L-GAGE

®

 LE250/550 Dual Discrete Laser

Sensors

 

 

Original Document

185580 Rev. C

6 November 2015

185580

Содержание L-GAGE LE250 IO-Link

Страница 1: ...ete Sensor Features Three LED indicators provide ongoing indication of the sensing status Power LED Indicator Solid Green Normal operation power On and laser On Flashing Green 1 Hz Power On and laser Off laser enable mode Discrete Output LED Indicators Solid Amber Discrete Output is On Off Discrete Output is Off Laser Description and Safety Information CAUTION Use of controls or adjustments or per...

Страница 2: ...PLIES WITH IEC 60825 1 2007 CLASS 1 LASER PRODUCT Output Complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice N o 50 dated June 24 200 7 Figure 3 FDA CDRH warning label Class 1 Laser wavelength 650 nm Output 0 22 mW Pulse Duration 150 µs to 900 µs Sensor Installation NOTE Handle the sensor with care during installation and operation Sensor windows soiled by finge...

Страница 3: ...d the bracket in the aligned position Wiring Diagrams 3 1 4 5 shield 2 12 30 V dc D1_Out D2_Out Input Load NPN PNP User configurable PNP NPN setting Load or Figure 9 Dual Discrete Models Key 2 3 4 1 5 1 Brown 2 White 3 Blue 4 Black 5 Gray Display Figure 10 LE550 Display in Run Mode The display is a 2 line 8 character LCD The main screen is the Run mode screen which shows the real time distance mea...

Страница 4: ...nges In the Sensor Menu a return arrow in the upper left corner of the display indicates that pressing Escape returns to the parent menu Press and hold Escape for 2 seconds to return to Run mode from any menu or remote teach Sensor Programming Program the sensor using the buttons on the sensor or the remote input limited programming options From Run mode use the buttons to access the Quick Menu an...

Страница 5: ...ress Enter to save the new value and return to the Quick Menu Quick Menu D1 SPt1 value Run Mode D1 SPt2 value D2 SPt1 value D2 SPt2 value Spt2 not available unless in Window Mode set value with or Save setting and return to Quick Menu Cancel and return to Quick Menu access Sensor Menu Top Menu Figure 12 Quick Menu Map Window Mode Sensor Menu MENU Access the Sensor Menu by pressing Enter from Run m...

Страница 6: ...Pt TchSPt2 Tch2Pt TchSPt1 WndSize 300 mm TchMdPt 500 mm TchMid TchMdPt TchMid WndSize Mode Health Mode Alarm Timer On1Sho Timer OffDly Polarity NPN Polarity PNP Mode SPt Mode SPt Mode Wnd Mode Wnd Active High Active Low Type LasrEnbl Type Teach Type SyncMstr Type SyncSlve Type Disabled Speed Standard Speed Fast Speed Medium Speed Slow Timer Off1Sho Timer OnDly AdjSPt2 1000 mm AdjSPt1 100 mm Sleep ...

Страница 7: ...x Low State 1 3 V at 1 6 mA max Measurement Output Rate Class 2 Laser Models 1 ms Class 1 Laser Models Fast 1 ms Class 1 Laser Models Std Medium Slow 2 ms Minimum Window Size LE250 1 mm 0 039 inches LE550 10 mm 0 39 inches Boresighting LE250 4 mm radius at 400 mm LE550 1 cm radius at 1 m Maximum Torque 2 N m 17 7 in lbs Indicators Power LED Indicator Solid Green Normal operation power On and laser...

Страница 8: ...nt protection may be provided with external fusing or via Current Limiting Class 2 Power Supply Supply wiring leads 24 AWG shall not be spliced For additional product support go to http www bannerengineering com Supply Wiring AWG Required Overcurrent Protection Amps 20 5 0 22 3 0 24 2 0 26 1 0 28 0 8 30 0 5 Performance Curves LE250 Dual Discrete Models LE550 Dual Discrete Models 0 6 0 5 0 4 0 3 0 ...

Страница 9: ...LUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGINEERING CORP B...