9.2.6 Rotation Range
Main Menu > Inspection > Motion > Rotation Range
Rotation Range is available when Motion is set to Match.
Rotation Range sets the expected rotation of parts or labels during an inspection. For example, a value of 45 means that the
part may rotate 45 degrees in either direction from the reference part and still pass. Move the slider from 0 to 180 degrees.
Note: The smaller the rotation range, the faster the inspection will run.
9.2.7 Edit Pattern
Main Menu > Inspection > Motion > Edit Pattern
Edit Pattern is available when Motion is set to Match.
The Edit Pattern feature allows pixels in a taught pattern to be removed, or restored after being removed. Click
Eraser to
remove pixels from the pattern. Click
Draw to restore removed pixels to the pattern.
9.2.8 Advanced
Main Menu > Inspection > Motion > Advanced
Advanced is available when Motion is set to Match.
Use the Advanced menu to enable Search ROI and Track with Motion. These options apply to all Match sensors in the
current inspection.
• Search ROI—Sets a custom region within the field of view to search for the pattern. When Search ROI is enabled,
both Teach and Search ROIs display. The Teach ROI is blue. The Search ROI is green or red, depending on whether
the sensor passes or fails.
• Track with Motion—Moves the ROIs with Motion. Motion must be enabled under Inspection > Properties.
9.2.9 Timeout
Main Menu > Inspection > Motion > Timeout
Timeout is available when Motion is set to Match.
Use Timeout to adjust the maximum time the inspection is allowed to execute. A timeout error is reported in the case the
inspection runs out of time.
9.3 Properties Menu
Main Menu > Inspection > Properties
Use the Properties menu to specify an Inspection Name, Inspection ID, and whether or not Motion is enabled. Motion is not
available for the Sort sensor.
Figure 51. Properties Menu
9.3.1 Inspection Name
Main Menu > Inspection > Properties > Inspection Name
iVu Plus TG and Color Gen2 Image Sensors
50
www.bannerengineering.com - Tel: + 1 888 373 6767