![Banner iVu Plus BCR Gen2 Series Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/banner/ivu-plus-bcr-gen2-series/ivu-plus-bcr-gen2-series_instruction-manual_4021075072.webp)
• Pass/Fail Output
• Inspection Name
• Sensor Result
◦
Pass/Fail
◦
Sensor Result (see
(p. 72) for additional information)
• Frame #
• Inspection Time (ms)
Table 7: Sensor Results
Sensor Type
Data to Export
Barcode
Barcode Count
Data Length
Symbol Type
Barcode Data
Data Export Sample Application
The iVu BCR installation package has a Data Export sample application that allows you to view exported data while setting
up the sensor, etc. In a production environment, you need to create your own application to process data exported from the
inspection.
Figure 61. Data Export Sample Application
13.1.5 Image Export
Image export is only supported on Ethernet ports. Inspection images are a maximum 752×480 8-bits per pixel grayscale
images in .bmp format. The images represent all the data in a full Field of View (FOV).
Each exported image is comprised of a header (64 bytes) followed by the image data. All 16- and 32-bit numeric entries are
little endian.
The header includes the following information:
Byte Offset
Field ID
Size in Bytes
Data Type
Description
0-15
Header Prefix
16
char
"IVU PLUS IMAGE"
16-19
Header Version
4
UInt32
2
20-23
Image Size
4
UInt32
Total number of bytes for exported image
24-27
Image Frame Number
4
UInt32
Image frame number
28-29
Image Width
2
UInt16
752 (maximum)
30-31
Image Height
2
UInt16
480 (maximum)
32-33
Image Format
2
UInt16
0: Bitmap, 1: JPEG
iVu Plus BCR Gen2 Series Sensor
72