EZ-SCREEN SLS Safety Light Curtain Instruction Manual
(1)
Standard 8-pin M12 QD cordsets can also be used, although the pin numbers and wire colors must be verified.
82
bn
wh
bu
bk
22 awg
Open
This application is considered to meet or exceed requirements for OSHA control reliability and safety categories 4 per ISO
13849-1.
QDE2R4-8..D Cable Pinout
(1)
Pin
Color
Description
1
brown (bn)
Ch 1a
2
No Connection
3
No Connection
4
Black (bk)
Ch 1b
5
Blue (bu)
Ch 2b
6
No Connection
7
No Connection
8
white (wh)
Ch 2a
When monitoring two individually mounted safety switches (as shown in
"Monitoring two positive-opening interlocking safety
), a faulty switch will be detected if it fails to switch as the guard opens. In this case, the
SLS
de-energizes its OSSD output and disables its reset function until the input requirements are met (i.e., the faulty switch
is replaced). However, when a series of interlocking safety switches is monitored by the
EZ-SCREEN SLS, the failure of one
switch in the system may be masked or not detected at all .
Monitoring two positive-opening interlocking safety switches
Figure 38.
Monitoring Series-Connected Positive-Opening Safety Switches
8.8.3
© Banner Engineering Corp.
Содержание EZ-SCREEN SLS
Страница 16: ...May 22 2023 EZ SCREEN SLS Safety Light Curtain Instruction Manual 16 Banner Engineering Corp...
Страница 52: ...Blank page 52...
Страница 68: ...Blank page 68...
Страница 90: ...Blank page 90...
Страница 102: ...Blank page 102...
Страница 106: ...Blank page 106...
Страница 114: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...