Value

PASS/FAIL

Description

300 to 600%

PASS

The difference of the taught conditions sufficiently exceeds the required minimum,

minor sensing variables will not affect sensing reliability

600% +

PASS

The difference of the taught conditions greatly exceeds the required minimum, very

stable operation

Percent Offset after SET

The Window, Dark, and Light SET methods will flash a % offset on the displays after a PASS or FAIL.

SET Result

% Offset Meaning

PASS (with % Offset)

Displays the % offset used for the SET method

FAIL (with % Offset)

Displays the minimum required % offset necessary to PASS the SET method

FAIL (without % Offset)

Presented condition cannot be used for the SET method

Threshold Alert or Threshold Error

Severe contamination/changes in the taught condition can prevent the Auto Thresholds algorithm from optimizing the

threshold(s).

State

Display

Description

Corrective Action

Threshold Alert

Alternates

 and

The threshold(s) cannot be

optimized, but the sensor's output

will still continue to function

Cleaning/correcting the sensing

environment and/or a re-teach of the

sensor is highly recommended

Threshold Error

The threshold(s) cannot be

optimized, and the sensor's output

will stop functioning

Cleaning/correcting the sensing

environment and/or a re-teach of the

sensor is required

DF-G1 Expert

 Dual Display Fiber Amplifier

 

 

P/N 161275 Rev. D

www.bannerengineering.com - Tel: +1-763-544-3164

9

Содержание Expert DF-G1-NS-2M

Страница 1: ...ion can cause either an energized or de energized sensor output condition Models Model Outputs Connector1 DF G1 NS 2M Single NPN 2 m 6 5 ft cable 4 wire DF G1 PS 2M Single PNP DF G1 KS 2M Dual outputs...

Страница 2: ...Installing the Fibers Follow these steps to install glass or plastic fibers 1 Open the dust cover 2 Move the fiber clamp forward to unlock it 3 Insert the fiber s into the fiber port s until they stop...

Страница 3: ...will result in the most reliable detection TRANSMITTER RECEIVER Single core fiber Multi core fiber Wiring Diagrams NPN Models Remote Programming N O 10 30V dc Load PNP Models Load 10 30 V dc Remote P...

Страница 4: ...ton is a 3 way button The positions are engaged by rocking the button left right The SET position is engaged by clicking down the button while the rocker is in the middle position All three button pos...

Страница 5: ...1234 Eco 123P diSP 1234 diSP 123P Eco 1234 Eco 123P display flips 180 1234 Gn 8 Fixed Gain Set To scroll through menu lists Press or To enter a choice list or to select and save Click SET To exit a ch...

Страница 6: ...ated signal Output OFF Output ON Darkest Taught Condition Lightest Taught Condition Position adjusted by Manual Adjust Figure 2 Two Point TEACH Light Operate shown The Output ON and OFF conditions can...

Страница 7: ...shown Output ON and OFF conditions can be reversed using the LO DO switch Light SET Sets a threshold a programmable offset below the presented condition Changes output state on any condition darker t...

Страница 8: ...presented and the sensor positions a threshold exactly at the presented condition When a condition lighter than the threshold is sensed the output either turns ON or OFF depending on the LO DO setting...

Страница 9: ...IL without Offset Presented condition cannot be used for the SET method Threshold Alert or Threshold Error Severe contamination changes in the taught condition can prevent the Auto Thresholds algorith...

Страница 10: ...ect or 150 mm 6 in cable with a 4 pin M12 Euro style quick disconnect or 150 mm 6 in cable with a 4 pin M8 Pico style quick disconnect Environmental Rating IEC IP50 NEMA 1 Operating Conditions Tempera...

Отзывы: