Instruction Manual

Original Instructions

Monitors emergency stop devices, such as palm buttons and rope/cable pulls,

and positive-opening safety switches used for guard/gate interlocking

The safety inputs can monitor:

A +24 V dc source switched by hard/relay contacts in single-channel

hookup, or

Hard/relay contacts in a dual-channel hookup using terminals S11-

S12 and S21-S22

The ES-FA-9AA has three normally open output switching channels for

connection to control-reliable power interrupt circuits

The ES-FA-11AA has two normally open output switching channels for

connection to control-reliable power interrupt circuits and one normally

closed auxiliary output channel

Automatic reset or monitored manual reset

Design complies with standards ANSI B11.19, UL991, ISO 13850 (EN418),

and ISO 13849-1 (EN954-1) (Safety Category 4)

For use in functional stop category 0 applications per ANSI NFPA 79 and IEC/

EN60204-1

6 or 7 amp safety output contacts, depending on model

Plug-in terminal blocks

24 V ac/dc operation

Models

Models

Supply Voltage

Outputs

Output Contact Rating

ES-FA-9AA

24 V ac/dc

3 Normally Open (NO)

6 A

ES-FA-11AA

2 Normally Open and 1 Normally Closed (NC)

7 A

WARNING: Not a Stand-Alone Safeguarding Device

This Banner device is not a stand-alone point-of-operation guarding device, as defined by

OSHA regulations. It is necessary to install point-of-operation guarding devices, such as safety light

screens and/or hard guards, to protect personnel from hazardous machinery. Failure to install point-

of-operation guards on hazardous machinery can result in a dangerous condition which could

lead to serious injury or death.

Important: Read this First

The user is responsible for satisfying all local, state, and national laws, rules, codes, and regulations relating to

the use of this product and its application. Banner Engineering Corp. has made every effort to provide complete

application, installation, operation, and maintenance instructions. Please contact a Banner Applications Engineer with any

questions regarding this product.

The user is responsible for making sure that all machine operators, maintenance personnel, electricians, and

supervisors are thoroughly familiar with and understand all instructions regarding the installation, maintenance, and use of

this product, and with the machinery it controls. The user and any personnel involved with the installation and use of this

product must be thoroughly familiar with all applicable standards, some of which are listed within the specifications.

Banner Engineering Corp. makes no claim regarding a specific recommendation of any organization, the accuracy or

effectiveness of any information provided, or the appropriateness of the provided information for a specific application.

Applicable U.S. Standards

ANSI B11 Standards for Machine Tools Safety

Contact: Safety Director, AMT – The Association for Manufacturing Technology, 7901 Westpark Drive, McLean, VA 22102,

Tel.: 703-893-2900

ES-FA-9AA and ES-FA-11AA E-Stop Safety

Module

 

 

Original Document

60606 Rev. G

12 August 2016

60606

Содержание ES-FA-11AA

Страница 1: ...and or hard guards to protect personnel from hazardous machinery Failure to install point of operation guards on hazardous machinery can result in a dangerous condition which could lead to serious inj...

Страница 2: ...vel of risk of harm These safety related functions can prevent initiation or they can stop or remove a hazard The failure of a safety related function or its associated safety circuit usually results...

Страница 3: ...turn to the closed contact armed position The switch must be a positive opening or direct opening type as described by IEC 60947 5 1 Standards ANSI NFPA 79 ANSI B11 19 IEC EN60204 1 and ISO 13850 spec...

Страница 4: ...ble local standards and codes Lockout tagout procedures may be required Refer to OSHA 29CFR1910 147 ANSI Z244 1 ISO 14118 or the appropriate standard for controlling hazardous energy It is not possibl...

Страница 5: ...rs associated with the operation of the machine to recognize and immediately correct such failures If you have any questions about your intended use please contact a Banner applications engineer Conne...

Страница 6: ...rdous area Reset switches must also be out of reach from within the safeguarded space and must be protected against unauthorized or inadvertent operation for example through the use of rings or guards...

Страница 7: ...Interfacing MSCs Warning MSC Monitor Contacts or Jumper A2 A1 S34 S33 S21 S11 S12 S22 dc common V ES FA 9AA 24V ac dc Auto Reset Manual Reset A2 No Connection Reset A1 S34 S11 S33 MSC1 MSC2 MSC3 S22...

Страница 8: ...evice A transformer with isolated windings A distribution system with multiple branch circuits capable of diverting energy of surges A capacitance capable of absorbing energy of surges A resistance or...

Страница 9: ...sed contact state e g arm the E stop switch to close its contacts Automatic reset Ch1 K1 and Ch2 K2 indicators should come ON and the safety output contacts should close Manual reset From an open cond...

Страница 10: ...the Module is not immediately replaced or repaired multiple simultaneous failures may accumulate such that the safety function can not be guaranteed Specifications Power General Supply Voltage and Cur...

Страница 11: ...VA 2 000 000 cycles at 250 VA 5 000 000 cycles at 125 VA Output Response Time 25 milliseconds typical Note Transient suppression is recommended when switching inductive loads Install suppressors acro...

Страница 12: ...CULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacem...

Отзывы: