background image

NOTE: For Window SET and Light SET, the maximum offset threshold percent is 90%.

Threshold position 

adjusted by 

Manual Adjust

Sensor positions
threshold a programmable
 % offset below the 
presented condition

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

Condition 
Presented

Figure 6. Light SET (Light Operate shown)

Light SET and Manual Adjust
Moves switching threshold value up or down to make adjustments

Slide Mode switch to ADJ to enter Adjust mode

Press "+" to increase; press "-" to decrease

GREEN display shows the switching threshold value

2 seconds after adjustment, the GREEN display will flash 3 times to confirm

Slide Mode switch to RUN to complete operation

Follow these steps to perform a Light SET:

Note: TEACH Selection must be programmed to Lt SEt (see 

Program Mode 

on page 5)

1. Enter Adjust Mode

Method

Action

Result

SET Button 11

Set Mode switch to ADJ

Display: Red - Signal Level; Green -

Threshold

Remote Input 12

No action is required; sensor is ready

for Light SET method

2. SET Sensing Condition

11 SET Button: 0.04 seconds 

 "Click" 

 0.8 seconds

12 Remote Input: 0.04 seconds 

 T 

 0.8 seconds

 

 

DF-G1 Expert

 Dual Display Fiber Optic Light Receiver

12

www.bannerengineering.com - tel: 763-544-3164

P/N 172436 Rev. C

Содержание DF-G1-NR-2M

Страница 1: ...dition Overview Figure 1 DF G1 Model Features 1 Output LED 2 LO DO Switch 3 RUN PRG ADJ Mode Switch 4 Lever Action Fiber Clamp 5 Red Signal Level 6 Green Threshold 7 SET Rocker Button Models Model Outputs Connector1 DF G1 NR 2M Single NPN 2 m 6 5 ft cable 4 wire DF G1 PR 2M Single PNP DF G1 NR Q5 Single NPN 150 mm 6 in PVC pigtail M12 Euro QD connector 4 pin DF G1 PR Q5 Single PNP DF G1 NR Q7 Sing...

Страница 2: ...3 Tighten the screws Remove from a DIN rail 1 Push the DF G1 up on the DIN rail 1 2 Pivot the DF G1 away from the DIN rail and remove it 2 Installing the Fibers Follow these steps to install glass or plastic fibers 1 Open the dust cover 2 Move the fiber clamp forward to unlock it 3 Insert the fiber s into the fiber port s until they stop 4 Move the fiber clamp backward to lock the fiber s 5 Close ...

Страница 3: ...tion is above the threshold for Window SET the output is ON when the sensing condition is inside the window In Dark Operate mode the output is ON when the sensing condition is below the threshold for Window SET the output is ON when the sensing condition is outside the window SET Rocker Button The SET rocker button is a 3 way button The positions are engaged by rocking the button left right The SE...

Страница 4: ...and search 176768 Run Mode Run mode allows the sensor to operate normally and prevents unintentional programming changes The SET rocker button is disabled during RUN mode except when using Window SET see Window SET on page 9 DF G1 Expert Dual Display Fiber Optic Light Receiver 4 www bannerengineering com tel 763 544 3164 P N 172436 Rev C ...

Страница 5: ... TEACH Selection Two Point TEACH Response Speed 50 ms Offset Percent 50 OFF Delay 0 Disabled OFF One Shot 0 Disabled ON Delay 0 Disabled ON One Shot 0 Disabled Display Readout Numeric ECO disabled Normal Orientation Gain Selection Auto Gain DF G1 Expert Dual Display Fiber Optic Light Receiver P N 172436 Rev C www bannerengineering com tel 763 544 3164 5 ...

Страница 6: ... and OFF conditions can be reversed by using the LO DO Light Operate Dark Operate switch see LO DO Switch in Top Panel Interface on page 3 Two Point TEACH and Manual Adjust Moves switching threshold value up or down to make adjustments Slide Mode switch to ADJ to enter Adjust mode Press to increase press to decrease GREEN display shows the switching threshold value 2 seconds after adjustment the G...

Страница 7: ...Method Action Result SET Button Move the Mode switch to RUN Display Red Signal Level Green Threshold Remote Input No action is required sensor returns to RUN mode automatically Dynamic TEACH Teaches on the fly Establishes a single switching threshold Threshold can be adjusted using and rocker button Manual Adjust Dynamic TEACH is best used when a machine or process may not be stopped for teaching ...

Страница 8: ... to RUN to complete operation Follow these steps to perform a Dynamic TEACH NOTE TEACH Selection must be programmed to dYn tcH see Program Mode on page 5 1 Enter Adjust Mode Method Action Result SET Button 5 Set Mode switch to ADJ Display Red Signal Level Green Threshold Remote Input 6 No action required sensor is ready for Dynamic TEACH method 2 Enter Dynamic TEACH Method Action Result SET Button...

Страница 9: ...be adjusted using and rocker button Manual Adjust Recommended for applications where a product may not always appear in the same place or when other signals may appear See Program Mode in the user s manual for programming the Offset Percent setting to increase decrease the window size A single sensing condition is presented and the sensor positions window thresholds a programmable offset above and...

Страница 10: ... increase press to decrease GREEN display shows the sensing window center value 2 seconds after adjustment the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Follow these steps to perform a Window SET Note TEACH Selection must be programmed to wind SEt see Program Mode on page 5 1 Enter Adjust Mode Method Action Result SET Button 8 Set Mode switch to ADJ...

Страница 11: ...Light SET Sets a threshold a programmable offset below the presented condition Changes output state on any condition darker than the threshold condition Threshold can be adjusted using and rocker button Manual Adjust Recommended for applications where only one condition is known for example a stable light background with varying darker targets See Program Mode on page 5 for programming the Offset ...

Страница 12: ... display shows the switching threshold value 2 seconds after adjustment the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Follow these steps to perform a Light SET Note TEACH Selection must be programmed to Lt SEt see Program Mode on page 5 1 Enter Adjust Mode Method Action Result SET Button 11 Set Mode switch to ADJ Display Red Signal Level Green Thres...

Страница 13: ...ondition causes the output to change state Threshold can be adjusted using and rocker button Manual Adjust Recommended for applications where only one condition is known for example a stable dark background with varying lighter targets See Program Mode on page 5 for programming the Offset Percent setting NOTE Offset Percent MUST be programmed to Minimum Offset to accept conditions of no signal 0 c...

Страница 14: ...d value 2 seconds after adjustment the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Follow these steps to perform a Dark SET Note TEACH Selection must be programmed to dr SEt see Program Mode on page 5 1 Enter Adjust Mode Method Action Result SET Button 14 Set Mode switch to ADJ Display Red Signal Level Green Threshold Remote Input 15 No action require...

Страница 15: ...l Adjust A single sensing condition is presented and the sensor positions a threshold exactly at the presented condition When a condition lighter than the threshold is sensed the output either turns ON or OFF depending on the LO DO switch setting see LO DO Switch in Top Panel Interface on page 3 Sensor positions threshold exactly at the presented condition Threshold position adjusted by Manual Adj...

Страница 16: ...ndition Accepted Displays read cAL SEt then flashes PASS Sensor returns to Adjust mode Threshold Condition Unacceptable Displays read cAL SEt then flashes FAIL Sensor returns to Adjust mode Remote Input Present sensing condition Single pulse the remote input T 3 Return to RUN Mode Method Action Result SET Button Move Mode switch to RUN Display Red Signal Level Green Threshold Remote Input No actio...

Страница 17: ...olarity overvoltage and transient voltages Delay at Power Up 500 milliseconds max outputs do not conduct during this time Output Configuration 1 current sinking NPN or 1 current sourcing PNP output depending on model Output Rating 100 mA max load derate 1 mA per C above 30 C OFF state leakage current 5 μA at 30 V dc ON state saturation voltage NPN 1 5 V PNP 2 V Output Protection Protected against ...

Страница 18: ...LE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS EXPENSES LOSSES LOSS OF PROFITS OR ANY INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STATUTE TORT STRICT LIABILITY NEGLIGENCE OR OTHERWISE Banner Engineering Corp reserves the right to change modify or improve the desi...

Отзывы: