All other conditions (lighter or darker) cause the output to change state

Sensing window center can be adjusted using "+" and "-" rocker button (Manual Adjust)

Recommended for applications where a product may not always appear in the same place, or when other signals may

appear

See Program Mode for programming the Offset Percent setting

A single sensing condition is presented, and the sensor positions window thresholds a programmable % offset above and below

the presented condition. In LO mode, Window SET designates a sensing window with the Output ON condition inside the window,

and the Output OFF conditions outside the window.

Sensor positions 
window thresholds 
a programmable %
offset from the 
presented condition

Darkest

(no signal)

Most Light

(saturated

signal)

Condition 

Presented

Sensing window

center adjusted by

Manual Adjust

Output OFF

Output OFF

Output ON

Figure 4. Window SET (Light Operate shown)

Output ON and OFF conditions can be reversed using the LO/DO switch.

Light SET

Sets a threshold a programmable % offset below the presented condition

Changes output state on any condition darker than the threshold condition

Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)

Recommended for applications where only one condition is known, for example a stable light background with varying

darker targets

See Program Mode for programming the Offset Percent setting

A single sensing condition is presented, and the sensor positions a threshold a programmable % offset below the presented

condition. When a condition darker than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO

setting.

Threshold position 

adjusted by 

Manual Adjust

Sensor positions
threshold a programmable
 % offset below the 
presented condition

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

Condition 
Presented

Figure 5. Light SET (Light Operate shown)

Dark SET

Sets a threshold a programmable % offset above the presented condition

Any condition lighter than the threshold condition causes the output to change state

Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)

Recommended for applications where only one condition is known, for example a stable dark background with varying

lighter targets

See Program Mode for programming the Offset Percent setting

Note: Offset Percent MUST be programmed to Minimum Offset to accept conditions of no signal (0 counts).

A single sensing condition is presented, and the sensor positions a threshold a programmable % offset above the presented

condition. When a condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO

setting.

DF-G1 Expert

 Dual Display Fiber Amplifier

 

 

P/N 161275 Rev. E

www.bannerengineering.com - Tel: + 1 888 373 6767

7

Содержание DF-G1 Expert

Страница 1: ...ch 4 Lever Action Fiber Clamp 5 Red Signal Level 6 Green Threshold 7 SET Rocker Button Models Model Outputs Connector1 DF G1 NS 2M Single NPN 2 m 6 5 ft cable 4 wire DF G1 PS 2M Single PNP DF G1 KS 2M...

Страница 2: ...Fibers Follow these steps to install glass or plastic fibers 1 Open the dust cover 2 Move the fiber clamp forward to unlock it 3 Insert the fiber s into the fiber port s until they stop 4 Move the fi...

Страница 3: ...grams NPN Models Load 10 30V dc Remote Programming N O 1 3 4 2 PNP Models Load 10 30V dc Remote Programming N O 1 3 4 2 Key 1 Brown 2 White 3 Blue 4 Black IO Link Models PUSH PULL 18 30 V dc Load Load...

Страница 4: ...engaged by clicking down the button while the rocker is in the middle position All three button positions are used during PRG mode to navigate the display driven programming menu During ADJ mode SET...

Страница 5: ...1234 Eco 123P diSP 1234 diSP 123P Eco 1234 Eco 123P display flips 180 1234 Gn 8 Fixed Gain Set To scroll through menu lists Press or To enter a choice list or to select and save Click SET To exit a ch...

Страница 6: ...on adjusted by Manual Adjust Figure 2 Two Point TEACH Light Operate shown The Output ON and OFF conditions can be reversed by using the LO DO Light Operate Dark Operate switch Dynamic TEACH Teaches on...

Страница 7: ...background with varying darker targets See Program Mode for programming the Offset Percent setting A single sensing condition is presented and the sensor positions a threshold a programmable offset be...

Страница 8: ...Thresholds are ON the Green display will flash Percent Minimum Difference after TEACH The Two Point and Dynamic TEACH methods will flash a minimum difference on the displays after a PASS or FAIL Value...

Страница 9: ...NPN or 1 current sourcing PNP output depending on model IO Link models 1 push pull and 1 PNP complementary outputs Repeatability High Speed 66 s Standard Long Range Extra Long Range 100 s Connections...

Страница 10: ...Y OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the dis...

Отзывы: