Factory Default Settings. The following settings are preset at the factory; revert sensor to factory defaults using
•
Dark Operate (DO)
•
50% DES
•
Health Mode Display
•
2% Threshold Offset Percentage
•
Normal Display Orientation
•
High Speed (HS)
Sensor Programming
Programming Procedures. Use the Dynamic (+) and Static (-) buttons to access and set programming parameters. For
remote programming, connect a switch or digital input to the gray wire (remote line); the length of the individual pulses is
equal to the value T when 0.04 seconds
≤
T
≤
0.8 seconds.
Returning to RUN mode. Exit Setup mode by stepping through the entire Setup process (see
4), by escaping out of the Setup process, or by exceeding the 60 second inactivity time-out. To escape out of the Setup
process, press and hold both the Static (-) and Dynamic (+) buttons for 2 seconds. (For remote programming, press and
hold the remote line for 2 seconds). The sensor always saves the selected settings and returns to Run mode.
Sensor Setup
•
Configures sensor display and operating parameters.
•
Changes are updated instantly.
•
Click Dynamic (+) or double-pulse remote line to select an option.
•
Click Static (-) or single-pulse remote line to advance.
Remote input pulse: 0.04 s
≤
T
≤
0.8 s
1. Access Setup mode.
Method
Action
Result
Push Button
Press and hold both the Dynamic (+) and
Static (-) buttons concurrently for more than 2
seconds
•
Arrow Icon 1 ON Red
•
Arrow Icon 2 OFF
•
Display shows “Threshold Offset
Percentage” option.
Remote Input
Double-pulse the remote line
2. Select the threshold offset percentage.
Method
Action
Result
Push Button
Click Dynamic (+) to toggle between selections
Click Static (-) to save selection and advance
to “Light/Dark Operate”
2% to 10% Threshold Offset Percentage:
“t 2,” “t 3,” “t 4,” “t 5,” “t 10”
Remote Input
Double-pulse remote line to toggle between
selections
Single-pulse the remote line to save selection
and advance to “Light/Dark Operate"
3. Select light operate or dark operate.
D10 Expert Series - Small Object Counter
4
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 146132 Rev. D