Banner D10 Expert Скачать руководство пользователя страница 10

D10 

Expert™ Discrete Output with Bargraph Display

Diffuse Mode

Performance based on 90% reflectance white test card

Performance Curves

3.93"

7.87"

11.81"

3.93"

7.87"

11.81"

400 mm
(15.74")

320 mm
(12.59")

240 mm

(9.45")

160 mm

(6.30")

80 mm
(3.15")

0

0

100 mm

200 mm

300 mm

100 mm

200 mm

300 mm

0

DISTANCE

0

0

0.39"

0.78"

1.18"

0.39"

0.78"

1.18"

60 mm
(2.36")

48 mm
(1.90")

36 mm
(1.42")

24 mm
(0.94")

12 mm
(0.47")

0

10 mm

20 mm

30 mm

10 mm

20 mm

30 mm

DISTANCE

BEAM WIDTH

BEAM WIDTH

PIT16U

PIT46U

PIT66U

PIT26U

1

10

100

1000

E

X

C

E

S

S

G

A

I

N

DISTANCE

1

10

100

10 mm

(0.4")

100 mm

(4.0")

1000 mm

(40.0")

1 mm
(.04")

10 mm

(0.4")

100 mm

(4.0")

1000 mm

(40.0")

1 mm
(.04")

1000

E

X

C

E

S

S

G

A

I

N

DISTANCE

PIT16U

PIT46U

PIT66U

PIT26U

0.59"

1.18"

1.77"

2.36"

0.59"

1.18"

1.77"

2.36"

0

15 mm

30 mm

45 mm

60 mm

15 mm

30 mm

45 mm

60 mm

0

DISTANCE

0.08"

0.16"

0.23"

0.31"

0.08"

0.16"

0.23"

0.31"

20 mm
(0.78")

16 mm
(0.63")

12 mm
(0.47")

8 mm

(0.31")

4 mm

(0.16")

0

0

2 mm

4 mm

6 mm

8 mm

2 mm

4 mm

6 mm

8 mm

0

DISTANCE

120 mm

(3.54")

96 mm
(2.83")

72 mm
(2.12")

48 mm
(1.42")

24 mm
(0.71")

0

PIT16U

PIT46U

PIT66U

PIT26U

BEAM WIDTH

BEAM WIDTH

50 mm
(1.97")

40 mm
(1.57")

30 mm
(1.18")

20 mm
(0.78")

10 mm
(0.39")

0

0

10 mm

20 mm

30 mm

10 mm

20 mm

30 mm

0

0.39"

0.78"

1.18"

0.39"

0.78"

1.18"

0.02"

0.04"

0.02"

0.02"

0.04"

0.06"

DISTANCE

5 mm

(0.19")

6 mm

(0.23")

4 mm

(0.16")

3 mm

(0.12")

2 mm

(0.08")

1 mm

(0.04")

0

0

0.5 mm

1.0 mm

1.5 mm

0.5 mm

1.0 mm

1.5 mm

0

DISTANCE

BEAM WIDTH

BEAM WIDTH

PBT46U

PBT66U

PBT26U

Opposed Mode

Green Beam Models

Diffuse Mode

Performance based on 90% reflectance white test card

Red Beam Models

1

10

100

1000

E

X

C

E

S

S

G

A

I

N

DISTANCE

1

10

100

10 mm

(0.4")

100 mm

(4.0")

1000 mm

(40.0")

1 mm
(.04")

10 mm

(0.4")

100 mm

(4.0")

1000 mm

(40.0")

1 mm
(.04")

1000

E

X

C

E

S

S

G

A

I

N

DISTANCE

PIT16U

PIT46U

PIT66U

PIT26U

E

X

C

E

S

S

G

A

I

N

DISTANCE

1

10

100

10 mm

(0.4")

100 mm

(4.0")

1 mm
(.04")

0.1 mm

(.004")

1000

E

X

C

E

S

S

G

A

I

N

1

10

100

10 mm

(0.4")

100 mm

(4.0")

1000 mm

(40.0")

1 mm
(.04")

0.1 mm

(.004")

1000

10000

DISTANCE

PBT16U

PBT46U

PBT66U

PBT26U

1

10

100

10 mm

(0.4")

100 mm

(4.0")

1 mm
(.04")

0.1 mm

(.004")

1000

E

X

C

E

S

S

G

A

I

N

DISTANCE

1

10

100

10 mm

(0.4")

100 mm

(4.0")

1 mm
(.04")

0.1 mm

(.004")

1000

E

X

C

E

S

S

G

A

I

N

DISTANCE

PBT46U

PBT66U

PBT26U

Opposed Mode

0.98"

1.97"

2.95"

3.93"

0.98"

1.97"

2.95"

3.93"

160 mm

(6.30")

128 mm

(5.04")

96 mm
(3.78")

64 mm
(2.52")

32 mm
(1.26")

0

0

25 mm

50 mm

75 mm

100 mm

25 mm

50 mm

75 mm

100 mm

0

DISTANCE

0

0

PBT16U

PBT46U

PBT66U

PBT26U

0.39"

0.59"

0.39"

0.19"

0.59"

0.19"

20 mm
(0.78")

16 mm
(0.63")

12 mm
(0.47")

8 mm

(0.31")

4 mm

(0.15")

0

10 mm

5 mm

100 mm

5 mm

10 mm

15 mm

DISTANCE

BEAM WIDTH

BEAM WIDTH

E

X

C

E

S

S

G

A

I

N

DISTANCE

D10BFP

Opposed Mode

PIT66U fibers

PIT46U fibers

1

10

100

1000

1.0 mm

0.04"

10.0 mm

0.4"

100 mm

4.0"

1000 mm

40.0"

1.0 mm

10.0 mm

100 mm

1000 mm

Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]

Содержание D10 Expert

Страница 1: ...alk avoidance routine for two sensors in Normal mode Selectable high speed HS mode option for 200 microsecond response Extreme configuration flexibility via push buttons or a remote input wire Easy se...

Страница 2: ...une the thresholds see page 8 Two push buttons Dynamic and Static or the remote wire may be used to access and set the sensing parameters Sensor sensitivity may be configured using any of three method...

Страница 3: ...emote Line 0 04 seconds T 0 8 seconds Result Access TEACH Mode Press and hold Static button 2 seconds No action required sensor is ready for 1st TEACH condition Power LED OFF Output LED ON Status LEDs...

Страница 4: ...t OFF Output ON Output ON Darkest Taught Condition Lightest Taught Condition Position adjusted by Manual Adjust Darkest no signal Most Light saturated signal Output OFF Output ON Position adjusted by...

Страница 5: ...remote line Window Accepted Power LED ON Bargraph 2 indicators flash together to show Window accepted Sensor returns to RUN mode with new settings Window Unacceptable Power LED OFF Bargraph 1 3 5 7 fl...

Страница 6: ...tons Manual Adjust Recommended for applications where only one condition is known for example a stable light background with varying darker targets A single sensing condition is presented and the sens...

Страница 7: ...han the threshold condition causes the output to change state Threshold position is adjustable using the and buttons Manual Adjust Recommended for applications where only one condition is known for ex...

Страница 8: ...5x T 0 8 seconds 2 seconds T T T T T T T T T T T T T T T T T T T T T T T T T T T T Push Button 0 04 seconds Click 0 8 seconds Remote Line 0 04 seconds T 0 8 seconds Result Access SETUP Mode Press and...

Страница 9: ...against output short circuit continuous overload transient over voltages and false pulse on power up Output Response Time 500 microseconds normal mode or 200 microseconds high speed mode Repeatability...

Страница 10: ...mm 0 08 1 mm 0 04 0 0 0 5 mm 1 0 mm 1 5 mm 0 5 mm 1 0 mm 1 5 mm 0 DISTANCE BEAM WIDTH BEAM WIDTH PBT46U PBT66U PBT26U Opposed Mode Green Beam Models Diffuse Mode Performance based on 90 reflectance w...

Страница 11: ...2 Screws 2 Hex Nuts 2 Bracket Dimensions Bracket included with Standard Sensor Models 61 3 mm 2 42 68 1 mm 2 68 10 5 0 2 mm typ 0 41 14 5 mm 0 57 Mounting Bracket included with some models 35 9 mm 1...

Страница 12: ...Brown 2 White 3 Blue 4 Black 5 Gray 6 Pink Not Used 6 Pin 6 Wire Pico 1 5 6 3 4 2 Quick Disconnect Cordsets Accessories SA DIN CLAMP Pair of metal DIN rail end stops slide onto DIN rail at either side...

Отзывы: