Asset Monitoring Gateway With SNAP ID Instruction Manual

 

 

 

23

Chapter Contents

Specifications for the Asset Monitoring Gateway with SNAP ID .......................................................................................................................  23
FCC Part 15 Class A for Intentional Radiators ..................................................................................................................................................  23

Industry Canada Statement for Intentional Radiators 

......................................................................................................................................  23

Banner Engineering Corp Limited Warranty 

.....................................................................................................................................................  23

 

Specifications for the Asset Monitoring Gateway with SNAP ID

Supply Voltage

 24 V DC (±10%) (use only with a Class 2 (UL) power supply 

or a Limited Power Source (LPS) (CE) power supply)

Power Consumption

9 W average; 30 W maximum

Mounting

A mounting system that provides for various mounting options 
has been provided with this enclosure.

To connect the mounting brackets, turn the enclosure such 
that the backside is visible. Place the mounting brackets over 

the bosses either horizontally, diagonally, or vertically, and fas­
ten them with the ¼”­20 x 0.25” SS, countersunk Philips drive 

screws provided (torque limit = 30 in. lbs.). The enclosure can 
be mounted vertically (on a wall) or horizontally (tabletop)

Enclosure Construction

ABS polycarbonate NON-UV Stabilized. Not for use outdoors.

Operating Conditions

–10 °C to +60 °C (+14 °F to +140 °F )

90% maximum relative humidity (non-condensing)

Environmental Rating

IP65

Certifications

Banner Engineering BV
Park Lane, Culliganlaan 2F bus 3
1831 Diegem, BELGIUM

FCC Part 15 Class A for Intentional Radiators

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the 
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is 
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not 

installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Op­

eration of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to 

correct the interference at his own expense.  

Industry Canada Statement for Intentional Radiators 

This device contains licence­exempt transmitters(s)/receiver(s) that comply with Innovation, Science and Economic Develop­
ment Canada’s licence­exempt RSS(s). Operation is subject to the following two conditions:

Cet appareil contient des émetteurs/récepteurs exemptés de licence conformes à la norme Innovation, Sciences, et 

Développement économique Canada. L’exploitation est autorisée aux deux conditions suivantes:

Banner Engineering Corp Limited Warranty 

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following 
the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at 

Product Support

Chapter 5 

This device may not cause interference. 

1. 

This device must accept any interference, including interference that may cause undesired operation of the device. 

2. 

L’appareil ne doit pas produire de brouillage. 

1. 

L’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en 
compromettre le fonctionnement. 

2. 

© Banner Engineering Corp.

Содержание AMG

Страница 1: ...Asset Monitoring Gateway with SNAP ID Instruction Manual Original Instructions p n 234288 Rev A July 17 2023 Banner Engineering Corp All rights reserved...

Страница 2: ...ecial Sensor Settings Screen 12 Initialize the VIBE IQ Machine Learning Algorithm 14 DXM Utilities Screens 16 HMI Utilities Screen 17 Chapter 4 Additional Information Push Information to BannerCDS 21...

Страница 3: ...r SNAP SIGNAL and Modbus equipped sensors Connected units can be grouped and renamed All relevant in put registers can have threshold alarms assigned to them individually The alarm status is indicated...

Страница 4: ...ith Ethernet connection M12 power and serial communications input connector PSW 24 1 power supply Polycarbonate enclosure STP M12 406 cordset not included with cellular models Mounting bracket packet...

Страница 5: ...AMG HMI Home Screen Customize the gateway name located on the top title bar by tapping Enter title and typing in a custom name For help information click the help information icon in the top right cor...

Страница 6: ...e to go to the main configuration device information menu Utilities screen 1 In the Sensor Utilities column touch Sensor Scan ID Assign The Sensor table will initially be unpopulated 2 Connect any sup...

Страница 7: ...new sensor converter at a time The gateway scans for new devices based on the default SID 1 so it is also important to change all identified devices SID when you will be adding more than one device To...

Страница 8: ...Blank page 8...

Страница 9: ...cted or has a communications issue Thrhld1 or Thrhld2 indicates an active threshold alarm depending on the alarm that is triggered ID Displays the current device Modbus Server ID Group If the sensor i...

Страница 10: ...the specific sensor Customize the sensor name by touching the text entry next to the name and entering a new name The details screen also provides a notes area intended for any applicable user data sp...

Страница 11: ...pendant light on the top left corner of the enclosure Critical alarms red take priority followed by yellow then green for normal operation indication Set thresholds for specific registers by touching...

Страница 12: ...e Sensor List Statistics screen Special Sensor Settings Screen The Special Sensor Settings screen contains the menus for specific sensor configurations including global Vibration algo rithm base setti...

Страница 13: ...inable ACTIVE ON values are the x axis and z axis velocity acceleration The sample period is the cycle time the al gorithm uses to deem a sample applicable The algorithm discards readings under the de...

Страница 14: ...d confirm The change is saved to the device locally and is stored to display in the sensor s statistics and data in all menus Sensor Custom Scaling IMPORTANT If you need to push sensor specific data t...

Страница 15: ...er of samples the gateway has available preferably up to 300 and the average value of the parameters is shown 2 Press Undo if more samples are required The suggested banked samples needed to accuratel...

Страница 16: ...CID fields only populate for cellular enabled devices DXM Configuration Contains options for pushing data to the Banner Cloud Data Services website The Cloud Push Enable toggle field de faults to No T...

Страница 17: ...168 0 1 using the internal XML configuration file DXM Network Configuration screen To manually change the IP address toggle the Ethernet Mode to Static Touch the Static IP Address fields and enter an...

Страница 18: ...tem Reset triggers an entire reset of the AMG Security Passwords Logout secures the device to the current configuration no settings can be changed without the administration password The default admin...

Страница 19: ...et Monitoring Gateway With SNAP ID Instruction Manual 19 System Messages Contains communication messages critical error messages global settings and sensor scan data HMI System Messages screen Banner...

Страница 20: ...Blank page 20...

Страница 21: ...ormation on creating accounts on and using the Banner Cloud Data Services CDS system please refer to the Banner CDS Quick Start Guide p n 201126 or the Instruction Manual p n 178337 Create a New Gatew...

Страница 22: ...s DXM Details screen 6 Click Save 7 On the HMI Go to DXM Utilities DXM Configuration to enable cloud pushing 1 Change the Threshold Filter to a number greater than 0 3 is recommended 2 Verify your dev...

Страница 23: ...are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency ener...

Страница 24: ...INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STATUTE TORT STRICT LIABILITY NEGLIGENCE OR OTHER WISE Banner Engineering Corp reserves the right to change modify or improve the...

Страница 25: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...

Отзывы: