Banner ABR 3000 series Скачать руководство пользователя страница 2

Laser Description and Safety Information

All ABR 3000 contain one aiming laser source used to position the reader. Disconnect the power supply when opening the device during main-

tenance or installation to avoid exposure to hazardous laser light. The laser beam can be switched on or off through a software command.
These products conform to the applicable requirements of IEC 60825-1 and comply with 21 CFR 1040.10 except for deviations pursuant to

Laser Notice N° 50, date June 24, 2007. This product is classified as a Class 1 M laser product according to IEC 60825-1 regulations.

CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in
hazardous radiation exposure. Do not attempt to disassemble this sensor for repair. A defective unit must be returned to
the manufacturer.

Class 1 lasers are lasers that are safe under reasonably foreseeable conditions of operation, including the use of optical instruments for intra-

beam viewing.

Installation Instructions

Set the Focus

The reader is factory-calibrated at three focus positions (45 mm, 70 mm, and 125 mm for WVGA models; 45 mm, 80 mm, and 125 mm for 1.2

MP models). The focus range is continuous to provide fine-tuning for your application. This means you can select a focus position different

than these three positions.

1. Determine the focus position needed for your application. The following tables show the reading ranges at the three focus positions

for Code 128 (1D) and Data Matrix (2D) 10 mil resolution codes.

Table 2: WVGA Models

Focus Position (mm)

Horizontal Field of View

Reading Range (Depth of Field)

1D

2D

45

38 mm (1.5 in)

30 mm to 80 mm (1.2 in to 3.1 in)

25 mm to 70 mm (1.0 in to 2.8 in)

70

56 mm (2.2 in)

60 mm to 125 mm ( 2.4 in to 4.9 in)

45 mm to 100 mm (1.8 in to 3.9 in)

125

95 mm (3.7 in)

95 mm to 155 mm ( 3.7 in to 6.1 in)

65 mm to 120 mm (2.6 in to 4.7 in)

Table 3: 1.2 MP Models

Focus Position (mm)

Horizontal Field of View

Reading Range (Depth of Field)

1D

2D

45

52 mm (2.0 in)

25 mm to 90 mm (1.0 in to 3.5 in)

30 mm to 65 mm (1.2 in to 2.6 in)

80

86 mm (3.4 in)

65 mm to 145 mm (2.6 in to 5.7 in)

55 mm to 105 mm (2.2 in to 4.1 in)

125

130 mm (5.1 in)

105 mm to 180 mm (4.1 in to 7.1 in)

80 mm to 125 mm (3.1 in to 4.9 in)

2. Using a 2.5 mm hex key, rotate the focus ring at the back of the reader to one of the three pre-calibrated distances or to the desired

distanced according to your application.

CAUTION: Do not rotate the focus ring beyond the focus scale limits; damage to the focus mechanism can oc-
cur.

Refer to the Reading Diagrams in the Instruction Manual which show the reading ranges at the different focus positions for Code 128

(1D) and Data Matrix (2D) codes.

Mount the Reader

Note: Mount the device at a 10° to 15° angle from the target to avoid direct reflections.

1. If a bracket is needed, mount the device onto the bracket.
2. Mount the device (or the device and the bracket) to the machine or equipment at the desired location. Do not tighten the mounting

screws at this time.

3. Check the device alignment.
4. Tighten the mounting screws to secure the device (or the device and the bracket) in the aligned position.

Connect the Cables

Table 4: Power and I/O Pinouts for MQDC2S-17xx

Pin

Wire Color

Name

Description

1

Brown

V dc

Power Supply Input V

2

Blue

GND

Power Supply Input Voltage -

3

White

NC

not connected

4

Green

NC

not connected

5

Pink

-

Reserved

6

Yellow

IN1

External Trigger (referenced to GND)

 

 

ABR 3000

2

www.bannerengineering.com - Tel: +1-763-544-3164

P/N 207636 Rev. A

Содержание ABR 3000 series

Страница 1: ...Serial Ethernet 1D ABR3106 WSU2 1 2 MP 1280 960 pixels 6 mm manual focus Serial USB 1D and 2D ABR3106 WSE2 Serial Ethernet 1D and 2D ABR3106 WSU1 Serial USB 1D ABR3106 WSE1 Serial Ethernet 1D ABR3106...

Страница 2: ...mm to 80 mm 1 2 in to 3 1 in 25 mm to 70 mm 1 0 in to 2 8 in 70 56 mm 2 2 in 60 mm to 125 mm 2 4 in to 4 9 in 45 mm to 100 mm 1 8 in to 3 9 in 125 95 mm 3 7 in 95 mm to 155 mm 3 7 in to 6 1 in 65 mm...

Страница 3: ...vides access to the following modes Icon Description Test Mode includes bar graph visualization to check static reading performance Focus Aim turns on the laser aiming cross to aim the reader at the t...

Страница 4: ...D stops blinking the ABR beeps once and exits Setup mode 3 If the calibration cannot be reached after a timeout of about 5 five seconds ABR exits without saving the parameters to memory the Setup LED...

Страница 5: ...n then on the Start menu click Control Panel or search for Control Panel b In Control Panel click Network and Internet then click Network and Sharing Center and then click Change adapter settings c Ri...

Страница 6: ...on the device For new devices the only saved configuration is the Default configuration 2 Click OK The device enters continuous mode and begins acquiring images 3 Place the application code in front...

Страница 7: ...ark ing Micro QR Code MAXICODE Aztec Code Australia Post Royal Mail 4 State Custom er Kix Code Japan Post PLANET POSTNET POSTNET BB Intelligent Mail Swedish Post FCC Statement Modifications or changes...

Страница 8: ...ty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGINEERING CORP BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXT...

Отзывы: