Banner 70960847 Скачать руководство пользователя страница 7

Specifications

Supply Voltage (Vcc)

12 to 30 V dc

Power and Current Consumption, exclusive of load

Normal Run Mode: 1.7 W, Current consumption < 70 mA at 24

V dc

Supply Protection Circuitry

Protected against reverse polarity and transient overvoltages

Sensing Beam

Class 2 laser models: visible red, 650 nm
Class 1 laser models: visible red, 650 nm

Sensing Range

LE250: 100 mm (3.94 in) to 400 mm (15.75 in)
LE550: 100 mm (3.94 in) to 1000 mm (39.37 in)

Output Configuration

Analog output: 4 to 20 mA or 0 to 10 V, depending on model
Discrete output rating: Discrete NPN/PNP is user-configurable

Output Ratings

Discrete Output: 100 mA maximum (protected against

continuous overload and short circuit)
OFF-state leakage current—PNP: < 10 µA at 30 V
OFF-state leakage current—NPN: < 200 µA at 30 V
Output saturation voltage—PNP outputs: < 3 V at 100 mA
Output saturation voltage—NPN outputs: < 1.6 V at 100 mA
Analog current output (LE...I Models):1 k

Ω

 max. @ 24 V;

max. load resistance = [(Vcc-4.5)/0.02 

Ω

]

Analog voltage output (LE...U Models): 2.5 k

Ω

 min. load

resistance

Delay at Power Up

2 s

Measurement/Output Rate

Class 2 laser models: < 1 ms
Class 1 laser models (fast): < 1 ms
Class 1 laser models (std/med/slow): < 2 ms

Ambient Light Immunity

Class 2 laser models: > 10,000 lux
Class 1 laser models: > 5,000 lux

Minimum Window Size, Analog and Discrete

LE250: 1 mm (0.039 in)
LE550: 10 mm (0.39 in)

Boresighting

LE250: 4 mm radius at 400 mm
LE550: 1 cm radius at 1 m

Remote Input

Allowable Input Voltage Range: 0 to Vcc
Active Low (internal weak pullup—sinking current):
· High State > 4.3 V at 740 µA max.
· Low State < 1.3 V at 800 µA max.
Active High (internal weak pulldown—sourcing current):
· High State > 4.3 V at 1.7 mA max.
· Low State < 1.3 V at 1.6 mA max.

Analog Resolution

LE250: 100 mm to 250 mm: Less than 0.02 mm
LE250: 250 mm to 400 mm: Less than 0.2 mm
LE550: 100 mm to 600 mm: Less than 0.5 mm
LE550: 600 mm to 1000 mm: Less than 1 mm

Analog Linearity

LE250: Linearity is the less of Accuracy or 0.3% of full scale range

(± 0.9 mm) at any given distance
LE550: Linearity is the lesser of Accuracy or 0.5% of full scale

range (± 4.5 mm) at any given distance

Maximum Torque

2 N·m (17.7 in-lbs)

Repeatability

See Performance Curves

Temperature Effect

See Performance Curves

Accuracy

See Performance Curves

Construction

Housing: die-cast zinc
Window: acrylic

Vibration/Mechanical Shock

All models meet Mil. Std. 202 G requirements method 201A.

Also meets IEC 60947-5-2.

Typical Beam Spot Size1

x

y

Beam

Spot

Pattern

Distance (mm)

LE250 Models

LE550 Models

100

250

400

100

550

1000

x

3.2

2.1

1.2

8.4

10.5

12.1

y

2.2

1.5

0.9

3.5

4.2

4.9

Response Time

Class 1 Laser

Models

Class 2 Laser

Models

Fast 2

2 ms

2 ms

Standard

10 ms

5 ms

Medium

30 ms

15 ms

Slow

100 ms

50 ms

1 Beam spot size is calculated as 1.6 times the D4

σ

 measured value

2 Response time for lateral entry of object into measurement range < 5 ms

L-GAGE

®

 LE250/550 Analog-Discrete Laser Sensors

 

 

P/N 175093 Rev. E

www.bannerengineering.com - Tel: +1-763-544-3164

7

Содержание 70960847

Страница 1: ...status Analog Output LED Indicator Solid Amber Displayed distance is within the taught analog output window Off Displayed distance is outside the taught analog output window Power LED Indicator Solid...

Страница 2: ...LIES WITH IEC 60825 1 2007 CLASS 1 LASER PRODUCT Output Complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice N o 50 dated June 24 200 7 Figure 3 FDA CDRH warning lab...

Страница 3: ...put Load User configurable PNP NPN setting 4 20 mA 3 1 2 4 5 NPN or PNP Figure 9 Analog Current Model shield 12 30V dc D_Out A_Out Input Load User configurable PNP NPN setting 3 1 2 4 5 NPN or PNP 0 1...

Страница 4: ...es In the Sensor Menu a return arrow in the upper left corner of the display indicates that pressing Escape returns to the parent menu Press and hold Escape for 2 seconds to return to Run mode from an...

Страница 5: ...y Press Enter to access the switch points Press Down or Up to change the switch point to the desired value Press Enter to save the new value and return to the Quick Menu Quick Menu 4mA Pt value MENU 2...

Страница 6: ...300 mm TchMdPt 500 mm TchMid TchMdPt TchMid WndSize Mode Health Mode Alarm Timer On1Sho Timer OffDly Polarity NPN Polarity PNP Mode SPt Mode SPt Mode Wnd Mode Wnd Active High Active Low Type LasrEnbl...

Страница 7: ...ius at 400 mm LE550 1 cm radius at 1 m Remote Input Allowable Input Voltage Range 0 to Vcc Active Low internal weak pullup sinking current High State 4 3 V at 740 A max Low State 1 3 V at 800 A max Ac...

Страница 8: ...al fusing or via Current Limiting Class 2 Power Supply Supply wiring leads 24 AWG shall not be spliced For additional product support go to http www bannerengineering com Supply Wiring AWG Required Ov...

Страница 9: ...e during the warranty period This warranty does not cover damage or liability for misuse abuse or the improper application or installation of the Banner product THIS LIMITED WARRANTY IS EXCLUSIVE AND...

Отзывы: