Step 3

In this position, the handle of the Female must be rotated before the handle of the Male can rotate. Rotate the handle of the Female to 

the fully open position. When this handle is fully opened, the locking yoke will engage the cam levers and prevent the cam levers from 

being opened while the handle is in the fully open position. The handles should now be oriented as shown in Figure 4.

  

Step 4

After the handle of the Female has been fully opened, the handle of the Male can be rotated. Rotate the handle of the Male to the fully 

open position. The assembly is now opened and flow may begin. When both valves are fully opened the handles should be oriented as 

shown in Figure 5.

  

To close the valves and disconnect the couplers, reverse steps 1 through 4.

Male

Female

Clamp Arm

Clamp Arm

!

!

WARNING!

As the handle of the Female is being closed and before the handle is fully closed, the locking yoke that 

prevents the cam levers from being opened will disengage. 

Make sure that the handle on the Female is fully closed before opening the cam levers.

If the cam levers are opened before the handle of the Female is fully closed, liquid may spray or be  

discharged, which may result in significant injury or death. 

FIGURE 5

FIGURE 4

Содержание DM220AD

Страница 1: ...DM220 DM300 SERIES 2 FULL PORT 3 FULL PORT POLYPROPYLENE Dry Disconnects Liquid Handling Products...

Страница 2: ...o reduce the risk of accidental spillage Both handles have interlock buttons which prevent the handles from opening when the halves are separated and the handles are in the fully closed position The F...

Страница 3: ...lean and damage free prior to connection WARNING The Banjo DM220 and DM300 Series should not be used at pressures above the Maximum Pressure or at temperatures above the Maximum Temperature or below t...

Страница 4: ...into the female half After the assembly is together latch the clamp arms onto the mating rib on the male and rotate the clamp lever toward the female body This will couple the halves together and dep...

Страница 5: ...the handle of the Male to the fully open position The assembly is now opened and flow may begin When both valves are fully opened the handles should be oriented as shown in Figure 5 To close the valv...

Страница 6: ...g Replace if necessary 8 Reinstall end plate on valve Before tightening the end plate make sure that the handle and ball are in the closed position Tighten end plate bolts to 100 in lb of torque 9 Che...

Страница 7: ...Dry Mate Dry Disconnects 7 NOTE Please see banjocorp com for more product drawings...

Страница 8: ...Dry Mate Dry Disconnects 8 NOTE Please see banjocorp com for more product drawings...

Отзывы: