Dry-Mate Dry Disconnects
5
Step 3
In this position, the handle of the Female must be rotated before the handle of the Male can rotate. Rotate the handle of the Female to
the fully open position. When this handle is fully opened, the locking yoke will engage the cam levers and prevent the cam levers from
being opened while the handle is in the fully open position. The handles should now be oriented as shown in Figure 4.
Step 4
After the handle of the Female has been fully opened, the handle of the Male can be rotated. Rotate the handle of the Male to the fully
open position. The assembly is now opened and flow may begin. When both valves are fully opened the handles should be oriented as
shown in Figure 5.
To close the valves and disconnect the couplers, reverse steps 1 through 4.
Male
Female
Clamp Arm
Clamp Arm
!
!
WARNING!
As the handle of the Female is being closed and before the handle is fully closed, the locking yoke that
prevents the cam levers from being opened will disengage.
Make sure that the handle on the Female is fully closed before opening the cam levers.
If the cam levers are opened before the handle of the Female is fully closed, liquid may spray or be
discharged, which may result in significant injury or death.
FIGURE 5