Select the COM port (use USB/COM converter if no COM port is available).
-
Select Baud Rate 19.2K (recommended).
-
Disconnect DVD 2 from the mains.
-
Connect the diagnostic cable from the PC to the UART connector (P1104 ) on
PCB14, Keyboard (AVL).
-
Power up DVD 2 and wait 5 sec. before continuing.
-
Click ‘Write’.
NOTE!
When you click ‘Write’, it starts reading and then starts writing. When the writing
procedure is finished, a ‘check sum value’ is displayed. Compare this ‘check sum
value’ with the last four characters in the filename before .s32 (in this case = 5460).
Checksum value for both should be the same, this indicates successful programming.
-
Disconnect DVD 2 from mains and remove Service Cable.
-
Reboot the recorder.
Confirm the software version by using the ‘Software version read out’ procedure
described on page 4.9.
Compare
4.12 Software update
Содержание DVD 2
Страница 6: ...1...
Страница 28: ...3 16...
Страница 44: ...4 16...
Страница 53: ...5 Replace PCB05 AV Input 5 2 Remove top cover 5 3 Remove DVD 2 front Remove screws 3x TX10 Remove cable 5P1922...
Страница 62: ...6...
Страница 69: ......
Страница 70: ...Bang Olufsen DK 7600 Struer Denmark Phone 45 96 84 11 22 Fax 45 97 85 39 11 3538064 08 07...