49
ATI NO TX ALLOWED
EP 1 = 00
Av Panel or Connection between Socket
Unit and Test equipment
EP 1 = 01
Av Panel, Top Interface, or interface cable
(connection or cable)
4A
ATI TLG WAS BREAK SYNCHED
EP 1 = 00
Av Panel or Connection between Socket
Unit and Test equipment
EP 1 = 01
Av Panel, Top Interface, or interface cable
(connection or cable)
F8
APPLICATION ERROR
00
NO APPLICATION ERROR
No error
01
ILLEGAL TOP FEP TELEGRAM
SW bug, check for Master Unit/AP SW
update
02
INVALID KEY EVENT
SW bug, check for Master Unit SW
update
10
POWER FAIL 50MS
Power disconnected while BC2 not in
stanby, or SMPS
11
POWER FAIL 100MS
Power disconnected while BC2 not in
stanby, or SMPS
20
TRANSMISSION BUFFER TIMEOUT
SW bug, check for Master Unit SW
update
21
ILLEGAL PORT VALUE
Test equipment used wrong port value
30
TUNER ERROR
EP 1 = 02
RDS COMPONENT
(IC402) Tuner
EP 1 = 03
TUNER COMPONENT
(IC200) Tuner
EP 1 = 04
PLL COMPONENT
(IC200) Tuner
EP 1 = 05
STEREO DECODER COMPONENT
(IC300) Tuner
EP 1 = 06
LPC COMPONENT
(IC401) Tuner
EP 1 = 07
ST EEPROM COMPONENT
(IC203) Tuner
EP 2 = 00
NO ST ERROR
Use EP1
EP 2 = 01
ST WRITE ERROR
Use EP1
EP 2 = 02
ST READ ERROR
Use EP1
EP 2 = 03
ST CHKSUM ERROR
Use EP1
EP 2 = 04
ST READ ERROR ONLY FF
Use EP1
EP 2 = 05
ST BLOCK LIMIT
Use EP1
EP 2 = 06
ST EEPROM INVALID BLOCK
Use EP1
40
RMP STATUS ERROR
EP 1+2 = 0001
RMP START UP MEDIA
Use EP3
EP 3 = 01
RMP NO DISC
No error
EP 3 = 02
RMP INVALID MEDIA TYPE
No error
EP 3 = 03
RMP SUBCODE ERROR
No error
EP 3 = 04
RMP START UP TIMEOUT
DVDM, SW bug check for Master Unit
SW update
EP 3 = 05
RMP TOC ERROR
No error
EP 3 = 1E
RMP DOORS NOT CLOSED
SW bug, check for AP SW update
EP 3 = 20
RMP DRIVER NOT STARTED
SW bug, check for Master Unit SW
update
EP 1+2 = 0002
RMP GOTO TRACK
Use EP3
EP 3 = 06
RMP INVALID TRACK NO
No error
EP 3 = 07
RMP TRACK NOT FOUND TIMEOUT
DVDM, SW bug check for Master Unit
SW update
EP 1+2 = 0003
RMP STOP
Use EP3
EP 3 = 08
RMP STOP TIMEOUT
No error
EP 1+2 = 0004
RMP PAUSE
Use EP3
EP 3 = 09
RMP PAUSE TIMEOUT
No error
EP 1+2 = 0005
RMP PAUSE RELEASE
Use EP3
EP 3 = 0A
RMP PAUSE RELEASE TIMEOUT
No error
EP 1+2 = 0006
RMP WIND
Use EP3
EP 3 = 0B
RMP WIND TIMEOUT
No error
EP 1+2 = 0007
RMP REWIND
Use EP3
Service menu, English 5.7
Содержание BeoCenter 2
Страница 6: ...3 1 Overall block diagram Overall block diagram 3 1 3 1 Overall block diagram ...
Страница 7: ...3 2 Wiring diagram Wiring diagram 3 2 3 2 Wiring diagram ...
Страница 29: ...Replace Keyboard left Replace Keyboard left 1 3 5 Socket Unit 2 180º 4 6 1 ...
Страница 30: ...Replace Keyboard right Replace Keyboard right 1 4 Socket Unit 5 2 180º 3 6 2 ...
Страница 46: ...6 18 ...
Страница 53: ......
Страница 54: ...Bang Olufsen DK 7600 Struer Denmark Phone 45 96 84 11 22 Fax 45 97 85 39 11 3538001 11 03 ...