Service menu 3.5
32
ICB L7 RESOURCE STILL RUNNING
µP H8 Module
33
ICB L7 RESOURCE ALLREADY FREE
µP H8 Module
34
ICB L7 ILLEGAL IOP SERVICE
µP H8 Module
35
ICB L7 ILLEGAL IOP OBJECT
µP H8 Module
36
ICB L7 TELEGRAM FLUSHED
µP H8 Module
37
ICB L7 RESOURCE DISABLED
µP H8 Module
38
ICB L7 HW CLOCK ILLEGAL COMMAND
µP H8 Module
39
ICB L7 HW CLOCK ILLEGAL EVENT
µP H8 Module
3A
ICB L2 RETRANS LIMIT REACHED
µP H8 Module
3B
IIC COMPONENT DISABLED
µP H8 Module
3C
POWER DOWN OF IOP IMPOSSIBLE
µP H8 Module
3D
CSD BUS DISABLED
SW bug, check for AP SW update
3F
ATI OVERRUN ERROR
EP 1 = 00
Av Panel or Connection between Socket
Unit and Test equipment
EP 1 = 01
Av Panel, Top Interface, or interface cable
(connection or cable)
40
ATI NACK
EP 1 = 00
Av Panel or Connection between Socket
Unit and Test equipment
EP 1 = 01
Av Panel, Top Interface, or interface cable
(connection or cable)
41
ATI NACK NO BUF
EP 1 = 00
Av Panel or Connection between Socket
Unit and Test equipment
EP 1 = 01
Av Panel, Top Interface, or interface cable
(connection or cable)
42
ATI NACK BAD SEQ
EP 1 = 00
Av Panel or Connection between Socket
Unit and Test equipment
EP 1 = 01
Av Panel, Top Interface, or interface cable
(connection or cable)
43
ATI NACK OVERRUN
EP 1 = 00
Av Panel or Connection between Socket
Unit and Test equipment
EP 1 = 01
Av Panel, Top Interface, or interface cable
(connection or cable)
44
ATI UNKNOWN PROTOCOL
EP 1 = 00
Av Panel or Connection between Socket
Unit and Test equipment
EP 1 = 01
Av Panel, Top Interface, or interface cable
(connection or cable)
45
ATI TIMEOUT NO RESPONSE
EP 1 = 00
Av Panel or Connection between Socket
Unit and Test equipment
EP 1 = 01
Av Panel, Top Interface, or interface cable
(connection or cable)
46
ATI DRIVER DISABLED
EP 1 = 00
Av Panel or Connection between Socket
Unit and Test equipment
EP 1 = 01
Av Panel, Top Interface, or interface cable
(connection or cable)
47
ATI UART DONT EXIST
EP 1 = 00
Av Panel or Connection between Socket
Unit and Test equipment
EP 1 = 01
Av Panel, Top Interface, or interface cable
(connection or cable)
48
ATI BREAK SYNC ABORTED
EP 1 = 00
Av Panel or Connection between Socket
Unit and Test equipment
EP 1 = 01
Av Panel, Top Interface, or interface cable
(connection or cable)
ABO-CENTER
v/HENRIKSENS
ELEKTRONIK
Содержание BeoCenter 2
Страница 10: ...2 A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K ...
Страница 22: ...4 A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K ...
Страница 52: ...7 2 7 2 7 2 A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K ...
Страница 63: ...A B O C E N T E R v H E N R I K S E N S E L E K T R O N I K ...