Kaskode One Rev 1.1
20
Table 3
below shows the cartridge loading input resistance for the available values of Rsl. The
different step-up ratios are also shown (1:5, 1:10 and 1:20).
1:5
1:10
1:20
S1/S4 Table for Desired Rsl
See Section 2.2.3
Secondary Loading Resistance (Rsl)
Ω
MC Cartridge Load Resistance (Zp) Ω
47000
1910
478
119
39000
1590
398
99
30000
1230
308
77
20000
830
208
52
15000
630
158
39
10000
430
108
27
5586
254
63
16
3170
157
39
10
1000
70
18
4
Rsl value of 3170
Ω
is not recommended for 1:20 step-up ratio. Rsl value of 1000
Ω
is not recommended for 1:10 and 1:20 step-up ratios.
These setting can be experimented with but may not achieve desirable results.
Table 3: Cartridge loading based on Rsl