Device description • Operating and connection elements
Power Panel C70 User's manual V1.30
75
3.6.1.2 "OPS" LEDs - Variant without fieldbus interfaces
LEDs "OPS1" to "OPS5" do not have a function for Power Panel variants without fieldbus interfaces
(4PPC70.xxxx-20x).
3.6.1.3 "OPS" LEDs - Variant with 2x CAN bus
Some Power Panel variants only have integrated terminating resistors starting with a certain hardware revision.
See the technical data for information about the hardware revision and system requirements of Automation Studio
and Automation Runtime for switching the terminating resistors.
Applies to hardware revisions with terminating resistors
LED
Color
Status
Description
Interface
OPS1
-
-
Reserved.
-
Off
Terminating resistor not switched on.
OPS2
Yellow
On
Terminating resistor switched on.
OPS3
Yellow
On
TxD/RxD: Data is being transmitted or received.
IF6: CAN bus
OPS4
Yellow
On
TxD/RxD: Data is being transmitted or received.
Off
Terminating resistor not switched on.
OPS5
Yellow
On
Terminating resistor switched on.
IF7: CAN bus
Applies to hardware revisions without terminating resistors
LED
Color
Status
Description
Interface
OPS1
-
-
Reserved.
-
OPS2
Yellow
On
RxD: Data is being received.
OPS3
Yellow
On
TxD: Data is being transmitted.
IF6: CAN bus
OPS4
Yellow
On
RxD: Data is being received.
OPS5
Yellow
On
TxD: Data is being transmitted.
IF7: CAN bus
3.6.1.4 "OPS" LEDs - Variant with 1x CAN bus and 1x RS232
Some Power Panel variants only have integrated terminating resistors starting with a certain hardware revision.
See the technical data for information about the hardware revision and system requirements of Automation Studio
and Automation Runtime for switching the terminating resistors.
Applies to hardware revisions with terminating resistor
LED
Color
Status
Description
Interface
OPS1
-
-
Reserved.
-
Off
Terminating resistor not switched on.
OPS2
Yellow
On
Terminating resistor switched on.
OPS3
Yellow
On
TxD/RxD: Data is being transmitted or received.
IF6: CAN bus
OPS4
Yellow
On
TxD/RxD: Data is being transmitted or received.
IF8: RS232
OPS5
-
-
Reserved
-
Applies to hardware revisions without terminating resistor
LED
Color
Status
Description
Interface
OPS1
-
-
Reserved.
-
OPS2
Yellow
On
RxD: Data is being received.
OPS3
Yellow
On
TxD: Data is being transmitted.
IF6: CAN bus
OPS4
Yellow
On
RxD: Data is being received.
OPS5
Yellow
On
TxD: Data is being transmitted.
IF8: RS232