background image

Accessories  • Optional accessories

20

ETAL210.1030-1 user's manual V1.00

X20CP1382

ETAL100.3200-1F

For details and additional technical data, see the data sheets for the individual products.

2.2 ETAL100.1Y05-0

2.2.1 General information

Using a Y-cable, it is possible to supply two ETA light systems using only one power supply unit. Many products

from the ETA light system can be supplied together due to the low power consumption.

ETAL100.1Y05-0 - 24VDC-Y cable, 5.5 x 2.1 male connector

Supplies two ETA light systems with one power supply unit

2.2.2 Order data

Model number

Short description

Figure

Accessories

ETAL100.1Y05-0

ETA light system Y-current distributor, for connecting two ETA

light systems to a desktop power supply unit, 1x DC 5.5 x 2.1 mm

female connector, 2x DC 5.5 x 2.1 mm male connector, max.

current 5 A, max. voltage 24 VDC, length including connections:

45 cm

Table 11: ETAL100.1Y05-0 - Order data

2.2.3 Technical data

Model number

ETAL100.1Y05-0

General information

Input voltage

Max. 24 VDC / Max. 2.5 A

B&R ID code

0xEBE7

24 VDC power supply

Connection

Low voltage female connector 5.5 mm / 2.1 mm (0TP650.07)

Cable construction

Wire cross section

On input 20 AWG / On output 24 AWG

Properties

Nickel-plated contacts

Outer jacket

Material

PVC

Mechanical properties

Length

450 mm

Table 12: ETAL100.1Y05-0 - Technical data

Содержание ETAL210.1030-1

Страница 1: ...ion in this document as far as legally possible Liability claims against B R regarding the content of delivery and documentation of third party components used in the product are excluded in any case...

Страница 2: ...products 5 Chapter 3 Safety notices 7 1 Safety notices 7 2 Usage 7 3 Electronics 7 4 Responsibilities of the operator 7 Chapter 4 System characteristics 8 1 General information 8 2 Order data 8 3 Con...

Страница 3: ...ctions or situations Signal word Description Danger Failure to observe these safety guidelines and notices will result in death severe injury or substantial damage to property Warning Failure to obser...

Страница 4: ...for proper ESD handling Electrical assemblies with housing Do not touch the connector contacts of connected cables Do not touch the contact tips on circuit boards Electrical assemblies without housin...

Страница 5: ...In combination with high temperature and relative humidity aggressive gases for example with sulfur nitrogen and chlorine components trigger chemical processes that can very quickly impair or damage e...

Страница 6: ...include for example Installation of product updates Significant system modifications such as configuration changes Deployment of updates or patches for third party software non B R software Hardware r...

Страница 7: ...wired and prepared for use No additional wiring examples are required The power supply and communication e g Ethernet are implemented via cables with standard connector systems such as RJ45 Caution El...

Страница 8: ...rly ex pandable with other ETA light systems via POWERLINK com pact dimensions Required accessories ETAL100 0000 2 Black coated wooden plate with B R logo two milled grooves for holding ETA light syst...

Страница 9: ...eristics Content of delivery Chapter 4 System characteristics ETAL210 1030 1 user s manual V1 00 9 X20CP1382 ETAL100 3200 1F For details and additional technical data see the data sheets for the indiv...

Страница 10: ...ower supply Connection Low voltage female connector 5 5 mm 2 1 mm 0TP650 07 Mechanical properties Dimensions Width 300 mm Height 230 mm Depth 90 mm Weight 1 2 kg Brief overview Content of delivery Thi...

Страница 11: ...appliance power supply cable 0TP370 76 1x module bracket ETAL100 0000 2 Advice When combining with other products from the ETA light system product portfolio you may need ad ditional components For ad...

Страница 12: ...s emergency stops or emergency stop buttons remain accessible Caution Danger of falling Loose cables can result in injuries Make sure that the cables are laid cleanly 3 Safety Check the following elem...

Страница 13: ...page 7 4 Power supply Connect the ETA light system product with power supply unit 0TP650 07 see technical data which is available in the accessories Warning Sparking Plugging in devices when the power...

Страница 14: ...rained qualified personnel at B R Repair attempts by third parties are not permitted and result in the immediate loss of warranty and guarantee claims Do not tamper with B R products Tampering with B...

Страница 15: ...TA light system product portfolio you may need ad ditional components For additional information see the documentation of the product used 1 1 0TP370 76 1 1 1 General information Cold appliance power...

Страница 16: ...EC 320 C14 Fully enclosed plastic housing 1 2 2 Order data Model number Short description Figure Accessories 0TP650 07 Wide range desktop power supply unit for office and laboratory use output paramet...

Страница 17: ...A light system modules Sturdy wooden base plate Possible to connect up to 2 ETA light system modules Compact dimensions 1 3 2 Order data Model number Short description Figure ETAL100 0000 2 Black coat...

Страница 18: ...ined buttons Each with 1 red 1 yellow and 1 green illuminated actuator Potentiometer for analog value input 2 1 2 Order data Model number Short description Figure Simulation and input devices ETAL120...

Страница 19: ...tion with other X20 components is possible in principle but requires a thorough examination of whether the I O configuration matches the wiring of this product Information Check whether the terminal b...

Страница 20: ...del number Short description Figure Accessories ETAL100 1Y05 0 ETA light system Y current distributor for connecting two ETA light systems to a desktop power supply unit 1x DC 5 5 x 2 1 mm female conn...

Страница 21: ...r s manual V1 00 21 2 3 POWERLINK cables Short description Length POWERLINK cables 0 5 m X20CA0E61 00050 1 m X20CA0E61 00100 1 5 m X20CA0E61 00150 2 m X20CA0E61 00200 Length Tolerances for cable lengt...

Страница 22: ...10 1030 1 user s manual V1 00 2 5 X20CA0E61 xxxxx Dimensions Length xxxx 47 Pinout Male RJ45 connector Male RJ45 connector 1 8 Shield White Orange Orange White Green Blue White Blue Green White Brown...

Страница 23: ...e environment as possible 1 Separation of materials To ensure that devices can be recycled in an environmentally friendly manner it is necessary to separate out the different materials Component Dispo...

Страница 24: ...information 24 ETAL210 1030 1 user s manual V1 00 Publishing information B R Industrial Automation GmbH B R Strasse 1 5142 Eggelsberg Austria Telephone 43 7748 6586 0 Fax 43 7748 6586 26 office br aut...

Отзывы: