Software • BIOS options
104
Automation PC 510 User's Manual V 1.01
InsydeH2O Setup Utility Rev. *
Advanced
Console Redirection Setup
Console Serial Redirect <Enabled>
Information Wait Time <5 Seconds>
Serial Port <COM_A>
Terminal Type <PC_ANSI>
Baud Rate <57600>
Data Bits <8 Bits>
Parity <None>
Stop Bits <1 Bit>
Flow Control <None>
ACPI SPCR Table <Disabled>
F1
F9
Esc
Enter
F10
Help Select Item
Change Values Setup Defaults
Exit Select Menu
Select SubMenu
Save and Exit
F5/F6
Image 54: US15W Advanced - Console Redirection
BIOS setting
Meaning
Setting options
Effect
Enabled
Enables this function.
Console Serial Redirect
Option for setting the remote console. The Re-
mote Console enables you to access the BIOS
setup via the serial interface using a terminal em-
ulator (PuTTY or HyperTerminal).
Information:
This setting is automatically enabled
when using an APC511 without I/O
board and the mode/node switch posi-
tion "00" (default).
Disabled
Disables this function.
Information Wait Time
Option for setting the amount of time for the Re-
mote Console to wait before accessing the BIOS
for the first time.
0 Seconds, 2 Seconds,
5 Seconds, 10 Se-
conds, 30 Seconds
The Remote Console waits x seconds before
accessing the BIOS for the first time.
COM_A
Access via the COMA serial interface.
COM_B
Access via the COMB serial interface.
COM_C
Access via the COMC serial interface.
COM_D
Access via the COMD serial interface.
Serial port
Option for setting the serial interface.
All Ports
TBD
VT_100
Disables the VT100 convention (ASCII charac-
ter set).
Enables the VT100+ convention (ASCII charac-
ter set and support for color, function keys, etc).
VT_UTF8
Enables the VT-UTF8 convention (uses UTF8-
coding, to assign Unicode characters one or
more bytes).
Terminal type
Option for setting the keyboard input.
PC_ANSI
Enables the PC ANSI convention (extended
ASCII character set).
Baud rate
Option for setting the transfer rate of the serial
interface (bits per second).
1200, 2400, 4800, 9600,
19200, 38400, 57600, 115200
A transfer rate of x bit is enabled.
7 bits
Character length with 7 bits
Data bits
Option for setting the character length (data bits)
to use for serial communication.
8 bits
Character length with 8 bits
None
No parity bit used.
Even
An even number of parity bits is used.
Parity
Option for setting the parity bit to use for serial
communication.
Odd
An odd number of parity bits is used.
1-bit
1 bit is used as stop bit.
Stop bits
Option for setting the stop bits to use for serial
communication.
2-bit
2 bits are used as stop bit.
Flow control
Option for configuring the data flow control.
None
Data flow control not enabled.
Table 107: US15W Advanced - Console Redirection setting options