Programming guidelines
286
ACOPOSinverter P84 User's Manual 2.10
2.8.11.36 Direct power supply via the DC bus
This function is only available for inverters with nominal power ≥18.5 kW.
The direct power supply via the DC bus requires a protected direct current source with appropriate strength and
voltage as well as a suitably sized resistor and capacitor precharge contactor. Information on the data for these
components can be obtained from B&R.
The function "direct power supply via the DC bus" can be used to control the pre-charging contactor via a relay
or a logic input on the inverter.
Wiring example with R2 relay:
Power supply
DC bus
Power supply
Contactor
[POWER SUPPLY DC BUS] (dCO-)
Code
Name/Description
Factory settings
dCO-
[POWER SUPPLY DC BUS]
This function is only available for inverters with nominal power ≥ 18.5 kW.
dCO
[Assign. charge ZK]
[No]
(nO)
Logic output or control relay
nO
[No]
(nO)
: Function not assigned.
r2
[CONFIGURATION R2]
(r2)
dO1
[DO1]
(dO1)
: Analog output AO, which can be used as logic output. The parameter is accessible when
[CONFIGURATION AO1]
(AO1)
=
[No]
(nO)
.
Содержание ACOPOSinverter P84
Страница 2: ......
Страница 384: ...Accessories 384 ACOPOSinverter P84 User s Manual 2 10 8I0FT180 300 1 A Nm lb in 8I0FT180 300 1 25 221 3...
Страница 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Страница 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Страница 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Страница 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Страница 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Страница 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...