![B&R 8I84T200037.01P-1 Скачать руководство пользователя страница 161](http://html1.mh-extra.com/html/bandr/8i84t200037-01p-1/8i84t200037-01p-1_user-manual_460473161.webp)
Programming guidelines
ACOPOSinverter P84 User's Manual 2.10
161
Drive parameters (continued)
Code
Name/Description
Setting range
Factory settings
OFI
[Sine-wave filter]
[No]
(nO)
nO
[No]
(nO)
: No sine-wave filter
YES
[Yes]
(YES)
: Use of a sine-wave filter to limit overvoltages of the motor and reduce leakage current to ground.
Der
[Sine-wave filter]
(OFI)
is forced to
[No]
(nO)
with the following types of inverters: 8I84T200037.01P-1 and 8I84T400075.01P-1.
Note:
The settings of
[Current limiting]
(CLI)
and
[2nd current limit]
(CL2)
must be performed after this configuration of
[Sine-wave filter]
(OFI)
=
[Yes]
(YES)
and
[Motor control type]
(Ctt)
=
[V/f Reg 2P]
(UF2)
or
[V/f Reg 5P]
(UF5)
as this configuration
results in a factory setting with reduced current limiting (1.36 In) for certain models.
Caution!
If
[sine-wave filter]
(OFI)
=
[Yes]
(YES)
,
[Motor control type]
(Ctt)
see "Drive parameters (Ctt)" on page 153
) must be
[V/f Reg 2P]
(UF2)
,
[V/f Reg 5P]
(UF5)
, (or for 8I84T2*****.01P-1 and 75 KW 8I84T4*****.01P-1
[SVC U]
(UUC)
only up to 45 kW) and
[Max. output freq.]
(tFr)
is not permitted to exceed100 Hz.
Failure to follow this instruction can result in equipment damage.
SFr
[Switching freq.]
1)
Depending on the size
Depending on the size
Switching frequency setting.
Setting range:
Can vary between 1 and 16 kHz, but the minimum and maximum values and the default value, depending the inverter type, the
rated current (power and voltage) and the configuration of the parameter
[Sine-wave filter]
(OFI)
and
[Motor surge limit]
(SVL)
If the value is lower than 2 kHz, then
[current limit]
(CLI)
and
[2nd current limit]
(CL2)
,
see "Setting parameters (SFr - CL2)" on page 144
are limited to 1.36 In.
Adjustment with running inverter:
•
If the initial value is under 2 kHz, it can not be increased over 1.9 kHz during operation.
•
If the start value is greater than or equal to 2 kHz, during operation a minimum value of 2 kHz should be maintained.
Adaptation with stopped inverter: No restrictions.
Note:
In the event of excessive temperature rise, the inverter will automatically reduce the switching frequency and reset it once the
temperature returns to normal.
Note:
If
[Motor control type]
(Ctt)
see "Drive parameters (Ctt)" on page 153
) is set to
[FVC]
(FUC)
, it is not recommended to set the
switching frequency to a value below 2 kHz (to avoid unstable speeds).
Caution!
On inverters of the models 8I84T400075.01P-1 to 8I84T400400.01P-1, if the RFI filters are disconnected (operation on an IT system),
the inverter's switching frequency is not permitted to exceed 4 kHz.
Failure to follow this instruction can result in equipment damage.
CLI
[CURRENT LIMIT.]
1)
0 to 1.65 In
2)
1.5 In
2)
Used to limit the motor current.
The adjustment range is limited to 1.36 In if
[Switch frequency]
(SFr)
is under 2 kHz.
Note:
If the setting is less than 0.25 in, the inverter can remain in error mode
[output phase loss]
(OPF)
, if this has been enabled,
"THERM. MOTOR PROTECTION (tHt) and LOSS OF MOTOR PHASE (OPL)" on page 292
). If it is below the no-load current of
the motor, the limitation has no effect.
Caution!
Make sure that the motor is designed to this current, since these are susceptible to a demagnetization.
Failure to follow this instruction can result in equipment damage.
1)
This parameter can also be accessed via the
[SETTINGS]
(SEt-)
menu.
2)
In is the same as the rated current specified in the installation instructions and on the nameplate of the inverter.
Parameter that can be modified during operation or when stopped.
Содержание 8I84T200037.01P-1
Страница 2: ......
Страница 384: ...Accessories 384 ACOPOSinverter P84 User s Manual 2 10 8I0FT180 300 1 A Nm lb in 8I0FT180 300 1 25 221 3...
Страница 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Страница 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Страница 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Страница 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Страница 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Страница 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...