Power Panel 300/400 User's Manual V 2.30
3.6.1 Technical data
Features
4PP320.1505-31
B&R ID-Code
$A17F
Boot loader / Operating system
Automation Runtime
Processor
Type
Expanded command set
L1 cache
L2 cache
Floating point unit (FPU)
Cooling
Method
Geode LX800 500 MHz, 32-bit x86
MMX technology, 3D Now
128 KB (64 KB L cache / 64 KB D cache)
128 KB
Yes
Passive (heat sink)
Flash
2 MB (for firmware)
Memory
Type
Quantity
DDR SDRAM
128 MB
Graphics
Controller
Memory
Geode LX800
8 MB shared memory (reserved by main memory)
SRAM
Quantity
Battery-buffered
Remnant variables for AR (Automation
Runtime) in Power Fail Mode
-
Watchdog
Controller
MTCX
1)
Power failure logic
Controller
Buffer time
MTCX
-
Real-time clock (RTC)
Battery-buffered
Accuracy
-
At +25°C: typically 30 ppm (2.5 seconds)
2)
per day
Battery
Type
Removable
Lifespan
Backup capacitor (for changing battery)
Buffer time
-
Ethernet
Controller
Transfer rate
Connection
Cables
NE2000-compatible
Intel 82551ER
10/100 MBit/s
RJ45 twisted pair (10 Base T / 100 Base T)
S/STP (category 5)
-
CompactFlash
Type
Amount
Connection
Type I
1 slot
Primary IDE device
Table 50: Technical data - 4PP320.1505-31
Содержание Power Panel 300
Страница 2: ...2 Power Panel 300 400 User s Manual V 2 30 ...
Страница 4: ...4 Power Panel 300 400 User s Manual V 2 30 ...
Страница 6: ...6 Power Panel 300 400 User s Manual V 2 30 ...
Страница 20: ...20 Power Panel 300 400 User s Manual V 2 30 Table of contents ...
Страница 428: ...428 Commissioning User tips for increasing the display lifespan Power Panel 300 400 User s Manual V 2 30 ...
Страница 536: ...536 Standards and certifications International certifications Power Panel 300 400 User s Manual V 2 30 ...
Страница 608: ...Model number index 2 Power Panel 300 400 User s Manual V 2 30 ...
Страница 612: ...Index 4 Power Panel 300 400 User s Manual V 2 30 ...