Wireless charging system 210W specification

1.Product summary

Create a high frequency from an AC power source, along with the transmitting power in a non-con-
tact with the charge control circuit, this product is a revolutionary wireless charging system that 
has at the same time signal communication function.

System configuration and product configuration

Battery voltage : 24V DC
Available lead batteries : charging current is a thing of 7A or more

Product typecode Description of each part

① Charging unit

RCS210-PB24

・Charge to a battery is performed. 

・It monitors the battery voltage, 【voltage monitor signal H, 

M, L】 as, and output control device that is connected to this 

unit and passive head results.

・I will output to control external devices connected to this 

unit and passive head, the information signal on the “float 

charging start”, “charging”, “battery error”.

② Power Supply unit RCS240-AC1

・AC power supply is changed into high frequency. 

・In response to the input signal【start-up signal】, and sup-

plies the high frequency to active head.

・I will output to an external control device inzone signal vari-

ous signals and the active head is received.

③ Passive Head

RCS240PH

・The receiving power from the active head, and supplies 

power to the charging unit.

・I can carry in a non-contact to the active head and a variety 

of signal that is output from the charging unit.

④ Active Head

RCS240AH

・By electromagnetic coupling method, in a non-contact, 

make the power transmitted to the passive head.

・Receives various signals from the passive head, and then 

transmitted to the power supply unit.

Power Supply unit

Charging unit

Active head

Passive head

 Thermistor

24V 

lead battery

External control device

External control device

AC power supply

Power supply

Signal communication

Start-up signal

Voltage monitor signal H,M,L
Float charging signal
Charging signal
Error signal
Inzone signal

Voltage monitor signal H,M,L
Float charging signal
Charging signal
Error signal

Temperature control

  ferrite clamp

Содержание RCS Series

Страница 1: ...h for purchasing the Wireless charging system RCS210 of B PLUS lately Before using this Processor read this manual carefully and operate properly paying attention to the safety aspects Wireless chargi...

Страница 2: ...orbidden I indicates mandatory Please always run Caution Attention Caution I do not do the resolution and remodeling Failure to do so may result in fire electric shock or malfunction In addition there...

Страница 3: ...h as a power in excess of the rated voltage there is a risk of overheating fire or malfunction To contact a specialized dealer or installation of equipment installation the wiring Improper by doing in...

Страница 4: ...rself the standards and regulations to which the customer s system should conform The control communication device that is installed in the product there is no need for diploma radio station authoriza...

Страница 5: ...the wiring 13 Connection diagram 15 6 Method of operation 16 How to switch on a power supply 16 How to turn off the power 16 About basic charge 16 Image behavior of the output voltage and current valu...

Страница 6: ...power supply is changed into high frequency In response to the input signal start up signal and sup plies the high frequency to active head I will output to an external control device inzone signal v...

Страница 7: ...unit and power supply unit according to the battery voltage If there is no inzone passive head when you connect the power of the default from external control de vices that are connected to the chargi...

Страница 8: ...tion rating 19 6m sec2 10 55Hz Protection class IP20 Dimension 230 188 50 5 Weight 1 6kg Attachment hole dimensions 4 7x6 5 Connection Power supply connector Round 3 pin Communication connector Round...

Страница 9: ...Operating humidity 90 RH No condensation Insulation 50M Ohm Dielectric strength 1500 VAC 1min Shock rating 10G each axis to x y z Vibration rating 19 6m sec2 10 55Hz Protection class IP20 Dimension 3...

Страница 10: ...Charging unit at the male 3 pin round Power Connected to the Charging unit at the female 3 pin round Signal Connected to the Charging unit at the male D sub9 pin Signal Connected to the Charging unit...

Страница 11: ...e width of the X axis Y axis is the following table For example X axis equals a 10mm Y axis 0mm If X axis is 5mm Y axis is less than 5mm If the product is used outside the range you may or equipment d...

Страница 12: ...the head with an interval greater than or equal to the value shown in the table below always Head For R bending of the cable line Please make the following is greater than or equal to the number of R...

Страница 13: ...oni tor signal Output Voltage monitor signal H 3 4 It is almost fully charged Charging aim about 90 Voltage monitor signal M 5 6 If the charge has been reduced somewhat Charging aim about 70 Voltage m...

Страница 14: ...ing ON in charge cut off and float charging start Inzone signal I I will if ON is in the transmission area within the Active head Passive head Error signal N It turns on if a battery error occurs 7 Ab...

Страница 15: ...eive an error due to the output such as a decrease occurs Connection diagram Passive Head Active Head Power cable Output cable 2 Thermistor with Cable 1 External device commu nication cable AWG28 16 1...

Страница 16: ...wer supply unit turns off after about 10 seconds the operation stopped A and B when the power can be transmitted within the range When the power is turned off LED of power supply unit is All off after...

Страница 17: ...ehavior of the output voltage and current value Operating to charging current 1 5A V V I A Output voltage Output current Output current 1 5A reach Float charging time CC charging time CV charging time...

Страница 18: ...less charging system 210W specification 30Ah 5 hour rate Battery discharge about 50 Characteristics Reference CC CV charging characteristics Time minutes voltage current Charging current A Charging vo...

Страница 19: ...alue I will move to this mode Charging voltage error Battery voltage outside of adaptation have been connected the voltage of the battery is down to abnormal Please connect the correct battery Battery...

Страница 20: ...0mm or more away the head and to face again in about one minute The OFF contact OFF the start up signal After about 1 minute turns ON the start up signal Communication function Communication machine i...

Страница 21: ...uired Up Inzone signal lights from entering the head transmission area 5s or less To start charging from the Inzone signal lights 5s or less Electric supply starting signal After ON if active head and...

Страница 22: ...te in the state of ON in a voltage monitor demand the voltage monitor signal according to battery residual quantity is outputted in several seconds It is necessary to output voltage monitor request fr...

Страница 23: ...23 Wireless charging system 210W specification...

Страница 24: ...Mail b plus usa b plus kk com Web http www b plus kk com Contents is subject to change without notice Wireless Power Supply by...

Отзывы: