![B&K CT1 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/bandk/ct1/ct1_user-manual_3077561006.webp)
CT-1 Back Panel
1. CT-1 IN MASTER
- 5 PIN Phoenix plug for connecting to a CT610/600/310 zone control I/O.
+12V - +12VDC power input for the CT-1
GND - Common ground for power and data
RCV - Receives RS-232 data to pass through to the RJ45 connector (RS-232 XMIT).
NC
- No connection
NC
- No connection
2. RS-232 XMIT
(Output)- RJ45 connector used for direct RS-232 linking between a CT
610/600/310 and B&K A/V Home Theater preamplifier/receiver. Install a straight through
CAT-5 cable when using this connection.
Note: This connector is intended for RS-232 XMIT and Ground and is not a source of VCC power.
3. HOME THEATER SENSOR
- 3 pin Phoenix plug for connecting to an IR Sensor or Keypad.
+12V - +12V power available for Home Theater IR Sensor or Keypad
IR IN - IR DATA IN from Home Theater IR Sensor or Keypad
GND - Common ground for power and data
Note: Both of the CT-1 HOME THEATER IR data inputs (IR-IN and IN), are summed together
internally.
4. CT 3 Flasher IN
- Nine 1/8" mini connectors. One CT Receiver is connected by nine 1/8” mini
jack interconnects. Each interconnect should be connected corresponding with the IR output
on the CT Receiver back panel. i.e. IR OUT 1 connects to Flasher IN 1, etc. These inputs
would also be used when chaining multiple CT-1’s.
5. CT 3 / Chain Out
- One 1/8" mini connector. To be used with an IR emitter for control of a
CT610/600/310. This output is a sum of IR Data from CT-1, CT-2 and Home Theater. Also,
this output is used when chaining multiple CT-1’s.
6. CT 2 Flasher IN
- Nine 1/8" mini connectors. One CT Receiver is connected by nine 1/8” mini
jack interconnects. Each interconnect should be connected corresponding with the IR output
on the CT Receiver back panel. i.e. IR OUT 1 connects to Flasher IN 1, etc.
CT-1 Back Panel
4
HOME THEATER
FLASHER OUT
CT 3 FLASHER IN
CT 2 FLASHER IN
9
CT 1 FLASHER IN
CHAIN
IN
CT IN MASTER
9
8
7
6
5
4
3
2
1
CT2
OUT
8
7
6
5
4
3
2
1
CT1
OUT
IN
RS-232
XMIT
ROUTING
RS-232
XMIT
SENSOR
9
8
7
6
5
4
2
1
CT3 / CHAIN
OUT
3
3
OUT
9
8
7
6
5
4
2
1
+12V
G
ND
RC
V
NC
NC
1
9
+12V
IR
IN
G
ND
SERIAL #
1
2
3 4
ON
5
6 7 8
9
ON
OFF
1
2
8
3
4
9
5
6
12
10
11
13
7