The
BANDIT 320
security fogging system is specifically designed to provide high reliability
and simple, quick and minimal maintenance requirements. Each
BANDIT 320
system
consists of a Fog Generator and an associated System Controller which is shown below.
Routine service consists of the procedures listed below.
The BANDIT 320 Recommended service schedule
1.
Annually (Not necessary, but recommended if opportunity arises)
(estimated time required 15
– 20 minutes)
•
Check that the green light is showing on the front of the Fog Generator, which
indicates the unit is operational.
•
Ensure there are no obstructions that may impede the fog output if the Fog
Generator was to activate.
2.
Every 2 Years (Required)
(estimated time required 25
– 30 minutes)
•
In addition to the annual requirements, replace the
Controller’s power supply
rechargeable battery.
•
Press the
‘Fog Isolation’ button on the Controller, to inhibit fog ejection.
•
‘Activate’ the
BANDIT 320
by conducting a ‘dummy test’ of the intruder alarm
system.
Whilst ‘isolated’ a successful activation will be confirmed by the Fog
Generator providing an audible ‘beep’ of approx. 3 seconds duration.
•
Reset your alarm system to normal mode
•
Once completed, press the ‘Fog Isolation’ button on the controller once again, to
return the system to normal status.
BANDIT 320
SERVICE & MAINTENANCE PROCEDURES