11
This procedure requires a reference boat speed with which to
compare the Network QUAD units displayed boat speed. For
example, another boat with an accurate
calibrated log, or if the top speed of the boat is known this
value can be entered during a sea trial to correct the
displayed value.
NOTE:
The accuracy of this method is dependant upon the
accuracy of the reference boat speed.
The example below shows a displayed boat speed of 5.2
knots, the boat speed is known to be 6.0 knots. The
displayed value is adjusted to read 6.0 knots.
IMPORTANT NOTE:
This method of calibration must not be
carried out at boat speeds of LESS THAN 3 KNOTS as
inaccurate values can be entered into the units memory. If
the speed and log are not functioning correctly then enter a
calibration value of 5.3 to 6.2 and then re-enter the correct
calibration value as described below.
Press
SPEED
key to display
current boat
speed.
Press
SETUP
key
three times to
display
CAL
.
Press
ENTER
key to adjust the
displayed value.
Use
!
or
"
to
change the value.
Press
ENTER
to
store the new
value in memory.
Press
SPEED
key to complete
the change.
METHOD 1. - MANUAL CALIBRATION - CAL