Head Room
The minimum height required between the highest point
of the door’s travel and the ceiling is 25mm.
Overhead Garage Door Opener Installation Instructions
PanelPro
TM
2
3
4
5
6
7
8
9
10
11
12
13
1
14
Kit Contents
1.
1 x PanelPro
TM
drive unit
2. 3 x Transmitters with batteries
3. 1 x Bent arm door attachment
4. 1 x Straight arm door attachment
5. 1 x Wall bracket TS01
6. 1 x Door bracket Locator
7. 1 x Door bracket
8. 3 x Pin Snap SSP 8 ZNU 31080
9. 2 x Hex Head screw M8x25
10. 1 x Pin 0890
11. 2 x Clevis Pin 0829
12. 2 x Hex Serration flange nut M8
13. 4 x Hex flange screw taptite ‘S’ M4 x 10
14. 1 x Wall/Visor Clip
PLUS
15. 2 x Track Bracket
16. 1 x Pre-Assembled Single Piece C-Rail
Important Safety Instructions
Locate shaft into
sprocket
Shaft
Hex flange screw taptite
‘S’ M4 x 10
Track bracket (x2)
Quick Install Guide
C-Rail Attachment
Single piece
C-Rails are pre-tensioned during
manufacturing for transport. Some
extra tension may be required after
installation.
If the C-Rail needs to be shortened
or lenghtened (using the extension
kit) ensure these modifications are
made to the drive unit end.
To prevent scratching the unit after
attaching the C-Rail, place the drive
unit back in its packing box.
Open to Determine your
Door Type
15
16
1
16
13
15
This automatic garage door opener is designed and tested to offer safe service provided it is
installed and operated in strict accordance with the following safety rules. Failure to comply with
the following instructions may result in death, serious personal injury or property damage.
WARNING!
Take car
e when testing or adjusting the Safety Obstruction Force.
Excessive force may cause SERIOUS PERSONAL INJUR
Y and/or PROPERTY
DAMAGE.
Testing Close Cycle
a.
Press the pr
ogrammed transmitter to open the door.
b.
Place a piece of timber approximately 40mm high on the floor dir
ectly under the door.
c.
Press the pr
ogrammed transmitter to close door.
d.
The door should strike the object and re-open.
Testing Open Cycle
a.
Press the transmitter to close the door
.
b.
Press again to open the door
.
c.
When the door reaches appr
oximately half way, fir
mly grab the door’s bottom rail - the
door should stop.
d.
If the door does not reverse r
eadily when closing, or stop when opening, the force may
be excessive and need adjusting.
40mm block of wood
Safety Obstruction Forces
T o Incr
ease Force Pr
essure
a.
Hold down FORCE MARGIN SET
button
.
b.
While holding
the FORCE
MARGIN SET
button, pr
ess the
PLUS (+)
button. Each press incr
eases the force mar
gin.
c.
The OPEN LIMIT LED
will flash each time the PLUS
(+) button is pressed
to indicate a force incr
ease
d.
If the OPEN LIMIT
LED is on continuously when pressing the
PLUS (+)
button, this indicates that the maximum setting has been reached.
e.
Test
the for
ce again
as per
Testing
Close Cycle
and Testing
Open Cycle.
WARNING!
If the door fails these tests, put
the opener
into manual
mode, only
operate
the door by hand and call for service.
WARNING!
Photo electric
beams must
be
installed if the closing force at the bottom
edge of the door exceeds 400N (40kg) force.
NOTE:
Once the travel limits ar
e set and safety obstruction for
ce tested check the chain or
belt tension. As per the sticker on the C-rail the chain or belt should sag slightly, so ther
e is
a 5mm gap between the bottom of the C-rail and the chain or belt.
The tension can be varied by using a spanner to adjust the bolt at the door end of the C-rail.
Be sure not to over
-tension the chain or belt as this can cause damage to the C-rail or
opener.
To Recall Factory Set For
ce
a.
While holding down the FORCE MARGIN SET
button, press the SET
button for two (2) seconds.
b.
Release both buttons. The default setting should now be recalled.
To Recalculate For
ce Margins
a.
Press and hold the FORCE MARGIN Button for six (6) seconds, the
beeper will sound once
.
b.
The door will start to move and re-calculate for
ce margins. The door can
move between the open and close limit positions up to four (4) times
(depending on the position of the door and the power up condition).
c.
A single beep will be heard once the pr
ocess is complete.
d.
T est the for
ce again as per T esting Close Cycle and T
esting Open Cycle.
Adjusting Safety Obstruction Force
The Safety Obstruction Force is calculated automatically during setup. Adjusting this is nor
mally
only necessitated by environmental conditions such as windy or dusty ar
eas, and areas with
extreme temperatur
e changes.
T o Decr
ease Force Pr
essure
a.
Hold down FORCE MARGIN SET
button.
b.
While holding the FORCE MARGIN SET
button, press the
MINUS (-)
button. Each press decr
eases the force mar
gin.
c.
The CLOSE LIMIT LED
will flash each time the MINUS
(-) button is
pressed to indicate a for
ce decrease.
d.
If the CLOSE LIMIT
LED is on continuously when pressing the
MINUS
(-) button this indicates that the maximum setting has been reached.
e.
Test
the for
ce again
as per
Testing
Close Cycle
and Testing
Open Cycle.
Symptom
Possible cause
Remedy
The opener does not work
from the transmitter
Garage door in poor condition e.g. springs
may be broken
The opener does not have power
The battery in the transmitter is flat
Transmitter does not contain T
ri-Tran
+
Technology
The opener has been put into “Vacation
Mode”
The transmitter button is not programmed to
operate the door.
Door Code LED is flashing yet the opener is
not working.
Check the door’s operation
Plug a device of similar voltage (e.g. a hairdryer) into
the power point and check that it is OK
Replace the battery
Check the transmitter has grey buttons and the model
number should display V2. Contact dealer for support
if otherwise.
Tur
n off “V
acation Mode”
Coding the transmitter
Ensure the corr
ect button on the transmitter is being
pressed.
One transmitter works but
the other/s do not
Faulty transmitter
Flat battery
Replace transmitter
Replace battery
The chain moves but the
door remains stationary
The opener is disengaged
Re-engage the opener
Motor is running but chain is
not moving
Damage motor assembly
Contact your dealer for support.
The transmitter range varies
or is restricted
Variations ar
e normal depending on
conditions e.g. temperature or exter
nal
interference
The battery life is exhausted
Position of the transmitter in the motor
vehicle
Make sure you can see the door when you use the
transmitter.
Check the battery status by pressing a button (flashing
or no light requir
es battery to be changed)
Aim the transmitter through the windscr
een.
The door reverses for no
apparent r
eason
This may occur occasionally from
environmental conditions such as ar
eas that
are windy
, dusty or have extreme temperatur
e
changes.
If Safety Beams are installed they may be
partially obstructed.
Ensure the door runs smoothly befor
e increasing the
force pr
essure.
Ensure the beam path is not obstructed. Check the
Alignment.
The SERVICE LED has
started to flash and is
beeping numerous times
A Fault has been detected. The fault will
be active each time an attempt is made to
operate the door.
Record opener function (How many beeps?) then pr
ess
the SET button once to reset the opener
. If the fault
continues to be tripped contact 1300 736 410 for
support.
The Open (Green) LED and
Close (Red) LED are flashing
alternatively
Opener is overloaded
Check the doors operation by disengaging the motor
and ensuring the door runs smoothly. If necessary make
door adjustments or contact your door professional.
The Open (Green) LED
continues to flash
Door obstructed when opening
Clear away any obstructions and test door opens
correctly
. (If door is damaged, contact your door
professionl).
The Close (Red) LED
continues to flash
Door obstructed when closing
Limits may be cleared
Clear away any obstructions and test door closes
correctly
. (If door is damaged, contact your door
professional).
Remove all power sources (including the battery
backup). Wait till all lights ar
e out (10-15 secs), then
reconnect power
. If Red LED is flashing, limits are not
set. Reset Limits.
Troubleshooting Guide
WARNING!
•
The door may operate unexpectedly, therefore do not allow anything to stay in the path of
the door.
•
When operating the manual release while the door is open, the door may fall rapidly due
to weak or broken springs, or due to being improperly balanced.
•
The drive must not be used with a door incorporating a wicket door, unless the drive cannot
be operated with the wicket door open.
•
The drive is intended to be installed at least 2.5m above the floor.
•
Do not disengage the opener to manual operation with children/persons or any objects
including motor vehicles within the doorway.
•
If the door is closing and is unable to re-open when obstructed, discontinue use. Do not
use a door with faulty obstruction sensing
•
When using auto close mode, a
Safety beam
must be fitted correctly and tested for
operation at regular intervals.
Extreme caution
is recommended when using auto close
mode.
All safety rules
must be followed.
ELECTROCUTION!
•
Place opener in protected area so that it does not get wet.
•
Do not spray with water .
•
Disconnect the power cord
from mains power before making any repairs or removing
covers. Only
experienced
service personnel should remove covers from the opener.
•
If the power cord is damaged, it
must
be replaced by an Automatic Technology service
agent or suitably qualified person.
•
Connect the opener to a properly
earthed
general purpose 240V mains power outlet
installed by a qualified electrical contractor.
CAUTION:
Emergency Access
•
If garage has no pedestrian entrance door, an emergency access device should be
installed. This accessory allows manual operation of the garage door from outside in case
of power failure.
Muscular strain
•
Practice correct lifting techniques (carton weighs approx 9kgs)
•
Practice correct lifiting techniques when required to lift the door as per installation instructions.
Fall from ladder
•
Ensure ladder is the correct type for job.
•
Ensure ladder is on flat firm ground that will take the weight without the legs sinking.
•
Ensure user has 3 points of contact while on ladder.
Garage Door
•
Examine the door installation, in particular cables, springs and mountings for signs of wear,
damage and imbalance.
•
The garage door must be
well balanced.
Sticking or binding doors must be repaired by a
qualified garage door installer prior to installation of the opener.
•
Remove or disengage
all garage door locks and mechanisms prior to installation of the
opener.
Entanglement
•
Never plug in and operate opener prior to installation.
•
Keep hands and loose clothing clear of door and guides at all times.
Entrapment under
operating door
•
DO NOT
operate the opener unless the garage door is in full view and free from objects
such as cars and children/people. Make sure that the door has finished moving before
entering or leaving the garage
•
In order for the opener to
sense
an object obstructing the door way, some
force
must be
exerted on the object. As a result the object, door and/or person may suffer minor
damage
or
injury.
•
Ensure the garage door is in good working order by undertaking regular servicing.
•
Install the optional wall transmitter in a location where the garage door is visible, but out
of the reach of children at a height of at least 1.5m.
•
Safety beams must be installed if the closing force at the bottom edge of the door exceeds
400N (40kg)
Tools Required
• Ladder
• Door Stand
• Adjustable Wrench
• Socket set
• Drill
• Screwdrivers
• Marker Pen
Power Supply
Properly earthed 3 pin single -phase power is required.
WARNING!
A portable power generator is
not recommended due to spikes, surges and
fluctuations in the supply.
Important Note:
Only Tri-Tran
+
Technology Transmitters
and Keypads are compatible with this
PanelPro product.
34-36 Marigold St, Revesby, NSW
, Australia ABN 25 010 473 971
P: 13 62 63 W: www
.bnd.com.au
Doc #: 161015_00
Part #: 79120
Released: 19/03/14
34-36 Marigold St, Revesby, NSW, Australia ABN 25 010 473 971
P: 13 62 63 W: www.bnd.com.au