5
ATTACH RAIL TO HEADER BRACKET
Position opener on garage floor below the header bracket. Use
packing material to protect the cover. Raise rail until holes in the
header sleeve and holes in the header bracket align. Join with
clevis pins (1). Insert ring fasteners (2) to secure.
NOTE:
To enable the rail to clear sectional door springs, it may
be necessary to lift opener onto a temporary support. The
opener must either be secured to a support or held firmly in
place by another person.
POSITION THE OPENER
SECTIONAL DOOR OR ONE-PIECE DOOR WITH TRACK
NOTE:
A 25mm board (1) is convenient for setting an ideal
door-to-rail distance (unless headroom is not sufficient).
Raise the opener onto a stepladder. Open garage door. Place a
25mm board
(1)
laid flat on the top section of door near the
centreline as shown. Rest the rail on the board.
If the raised door hits the trolley, pull down on the trolley release
arm to disconnect the trolley from the chain. The trolley can
remain disconnected until connecting door arm to trolley is
completed.
1
2
2
1
1
2
114A2991
INSTALL THE HEADER BRACKET
NOTE: Refer to vertical centre and horizontal lines created in
section “Position the Header Bracket” on page 4 for proper
placement of header bracket.
A
.
Wall Mount:
Centre the header bracket (1) on the vertical
centreline (2) with the bottom edge of the header bracket on
the horizontal line (4) (with the arrow pointing toward the
ceiling). Mark all of the header bracket holes (5). Drill 4.5mm
(3/16") pilot holes and fasten the header bracket with wood
screws (3).
B
.
Ceiling Mount:
Extend vertical centreline (2) onto the ceiling.
Centre the header bracket (1) on the vertical mark no more
than 150mm (6") from the wall. Make sure the arrow is pointing
toward the opener. Mark all of the header bracket holes (5).
Drill 4.5mm (3/16") pilot holes and fasten the header bracket
with wood screws (3). For concrete ceiling mount, use
concrete anchors provided.
2
50mm
(2")
3
1
4
A
B
150mm
(6")
1
2
3
5
5
1