performed to detect energy on
the channel. If the detected
energy is above the CCA
Threshold, the module will not
transmit the packet.
*Firmware version in which the command was first introduced (firmware versions are
numbered in hexadecimal notation.)
Commands-Sleep (Low Power)
AT_
Command
Command_
Category
Name and Description
Parameter
Range
Default
SM
Sleep_ (Low
Power)
Sleep Mode. <NonBeacon
firmware> Set/Read Sleep Mode
configurations.
0 – 5
0 = No Sleep
1 = Pin
Hibernate
2 = Pin Doze
3 = Reserved
4 = Cyclic
sleep
remote
5 = Cyclic
sleep
remote
w/ pin
wake-up
6 = [Sleep
Coordinator]
for
backwards
compatibility
w/ v1.x6
only; otherwise,
use CE
command.
0
ST
Sleep_ (Low
Power)
Time before Sleep.<NonBeacon
firmware> Set/Read time period of
inactivity (no serial or RF data is
sent or received) before activating
Sleep Mode. ST parameter is only
valid with Cyclic Sleep settings (SM
= 4 - 5). Coordinator and End
Device ST values must be equal.
Also note, the GT parameter value
must always be less than the ST
value. (If GT > ST, the
configuration will render the
module unable to enter into
command mode.) If the ST
parameter is modified, also modify
the GT parameter accordingly.
1 -0xFFFF
[x 1 ms]
0x1388
(5000d)