Section 4 - Configuring the Serial Server
Vlinx VESR4x4 Serial Server
Page 29 of 67
www.bb-elec.com/
www.bb-europe.com/
Figure 25.
Serial Port Configuration Page
1.
Mode
- select the type of serial connection (RS-232, RS-422, RS-485 2-
wire or RS-485 4-wire) required to connect the serial device to the serial
server.
2.
Baud Rate
- select the Baud Rate (between 75 baud and 230,400 baud)
required to communicate with the serial device connected to the serial
server.
3.
Data Bits
- select the number of Data Bits (5, 6, 7 or 8) required to
communicate with the serial device connected to the serial server.
4.
Stop Bits
- select the number of Stop Bits (1, 1.5, or 2) required to
communicate with the serial device connected to the serial server.
5.
Parity
- select the Parity setting (None, Even, Odd, Mark or Space)
required to communicate with the serial device connected to the serial
server.
6.
Flow Control
- select the Flow Control setting (None, RTS/CTS or
XON/XOFF) required to communicate with the serial device connected to
the serial server.
Setting up Port Network Parameters
On the
Port Network Parameters Configuration
page you can configure the
port to use UDP, TCP. VCOM or Paired protocols in several different modes.