background image

  

Using 

Telnet 

Manual Documentation Number: ESP901-902_4105m 

 Chapter 11 

65

 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – 

www.bb-elec.com

 

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – 

www.bb-europe.com

 

 

Figure 56. 

Telnet Configuration Screens 

 

Using Telnet 

66 

Chapter 11 

Manual Documentation Number: ESP904-0504 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – 

www.bb-elec.com

 

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – 

www.bb-europe.com

 

 

Step 7:

 Once all the changes have been made move to the 

Save

 field 

and select 

Enter

. The restart message will appear. 

 

Figure 57.  Saving and Restarting the Configuration 

Step 8:

   Select 

Yes

 to save changes. This is necessary to write the 

settings to the server. The Telnet window will disappear. 

Step 9:

 

 To view the changes re-enter 

Telnet

 and re-establish 

communications. The configuration menu will appear and 
display the current settings. 

Содержание RS-485

Страница 1: ...s s M Mo od de el ls s E ES SP P9 90 01 1 E ES SP P9 90 01 1E E E ES SP P9 90 02 2 E ES SP P9 90 02 2E E International Headquarters B B Electronics Mfg Co Inc 707 Dayton Road Ottawa IL 61350 USA Phone...

Страница 2: ...ange without notice and does not represent a commitment on the part of B B Electronics B B Electronics shall not be liable for incidental or consequential damages resulting from the furnishing perform...

Страница 3: ...17 Automatic Installation 17 Manual Installation 17 Updating an Existing Installation 19 Opening the ESP Manager 20 ii Table of Contents Manual Documentation Number ESP901 902_4105m B B Electronics M...

Страница 4: ...GURATION USING TELNET 63 Navigating the Configuration Menu 64 CHAPTER 12 ESP901 AND ESP902 TECHNICAL DATA 67 APPENDIX A RS 232 CONNECTIONS 71 SERIAL SERVER DB 9 PIN OUTS IN RS 232 MODE 71 RS 232 Strai...

Страница 5: ...ort 2 is RS 232 only 10 100 Mbps Ethernet with Auto Selection LAN and WAN Communications TCP or UDP Client or Server operation configurable Software Support Windows 98 ME 2000 XP or NT 4 0 Firmware Up...

Страница 6: ...network to the Serial Server which converts the IP packet back to serial data and sends the data out a serial port located on the Serial Server To use this mode the Serial Server must be set to eithe...

Страница 7: ...ox 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Pk Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Softwar...

Страница 8: ...and map it to an unused COM port e g Port 15 Configure it for TCP protocol and the appropriate IP address determined in the last section Figure 4 Configuring the Virtual COM Port Check Communications...

Страница 9: ...m B B Electronics Ltd Westlink Commercial Pk Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Indicator Lights Light Indication Power Red power is applied Link Yellow 10Bas...

Страница 10: ...ON position 2 With any DIP switch in the OFF position set the Server Properties Console Mode field to Console and Update Save the configuration Making Hardware Connections 12 Chapter 2 Manual Documen...

Страница 11: ...re single ended and referenced to Ground To use handshaking Flow Control must be set to RTS CTS during Configuration N No ot te e Refer to Appendix A for RS 232 connection pin outs Making Hardware Con...

Страница 12: ...it Data TXD Out TXDB Data B 4 Data Terminal Ready DTR Out TXDA Data A 5 Signal Ground GND GND GND 6 Data Set Ready DSR In CTSA 7 Request To Send RTS Out CTSB 8 Clear To Send CTS In RTSB 9 Ring Indicat...

Страница 13: ...tion Step 1a Inserting the VLINX CD in the CD ROM should automatically launch the Install Shield Wizard Manual Installation Step 1b To manually start the software installation from the Windows Desktop...

Страница 14: ...Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Pk Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 ww...

Страница 15: ...t port Set all the DIP switches on the Serial Server to the OFF position Figure 19 Ethernet Connection via a LAN Using ESP Manager 22 Chapter 4 Manual Documentation Number ESP901 902_4105m B B Electro...

Страница 16: ...guration information that will be displayed in the Server Properties window Uninstall Virtual COM Allows virtual COM ports to be uninstalled from the ESP Manager window Monitor Port Status Brings up a...

Страница 17: ...M port condition o Not Connected is shown when a program does not have the port Open o Connected is shown when that mapped port is Open for use Virtual COM List COM Name Displays the number of the COM...

Страница 18: ...urrently selected server Step 6 To open the Server Properties window highlight the Serial Server in the Serial Server List window double click to open The Server Properties window is used to configure...

Страница 19: ...rch Dialogue Box While the Serial Server is searching for all reachable servers the following dialogue box appears Figure 28 The Search VLINX ESP Dialogue Box After that port has been updated you may...

Страница 20: ...433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Pk Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Description of the Server Properties Figure 30 ESP Mana...

Страница 21: ...At run prompt enter CMD In the DOS window enter Ping xxx xxx xxx xxx IP address for the server to be confirmed The command will return the Ping results indicating 4 replies Figure 31 Pinging using the...

Страница 22: ...om communications are ideal for 5 seconds the Serial Server will reset and make itself available for another client connection TCP Alive Timeout The Serial Server monitors TCP activity If TCP activity...

Страница 23: ...e server to its default configuration RS 232 When this mode is selected and the server updated the selected serial port will become an RS 232 serial port on the server RS 422 When this mode is selecte...

Страница 24: ...Electronics Ltd Westlink Commercial Pk Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com After that port has been updated you may want to re enter Server Properties to veri...

Страница 25: ...Telnet These are located at the bottom of all three Web Server pages If a field is changed you must click Save before leaving that page or the changes will be ignored Figure 37 The Web Server Page N...

Страница 26: ...tions which allows the software to open a connection with the serial port located anywhere on the LAN WAN When using the virtual COM port the Serial Server is configured as a TCP or UDP Server Virtual...

Страница 27: ...one RTS CTS can be selected if used by the application program and serial hardware The Serial Server must be set to match Installing Virtual COM Port 46 Chapter 6 Manual Documentation Number ESP901 90...

Страница 28: ...Click the Configuration or Port Settings tab This screen allows the settings to be changed if necessary Click Cancel to keep the existing settings Step 5 Click OK to change the settings Use Refresh i...

Страница 29: ...1 From the Windows Desktop click Start Programs B B Electronics VLINX ESP Servers VLINX ESP Manager Step 2 In the ESP Manager window click the Virtual COM List tab Highlight the mapped COM port number...

Страница 30: ...o expand Figure 47 The Device Manager Window Step 4 Highlight ESP COM to be removed and click the Action tab at the top of window then clickUninstall A confirm Device Removal window will appear Removi...

Страница 31: ...ing a direct connection to upload the firmware to the Serial Server set the baud rate to 115200 for the fastest possible upload Step 3 Set the Serial Port field to upgrade and click the Update button...

Страница 32: ...via an RS 232 crossover cable Step 3 In the HyperTerminal Port Settings window set o Baud rate 9600 o Data bits 8 o Parity None o Stop bits 1 o Flow control None Click OK Step 4 Ensure all the DIP sw...

Страница 33: ...e Configuration The restart message will appear Step 6 Select Yes to save changes This is necessary to write the settings to the server Using a Password If a password is used it must be entered before...

Страница 34: ...plorer type the IP Address of the Serial Server into the address field near the top of the window and press the Enter key The following window will appear Figure 52 The Web Server Page Using the Web S...

Страница 35: ...s to the Serial Server Settings for each Port must be saved separately N No ot te e If new property settings are not saved before leaving this page they will not take effect Return to the main Server...

Страница 36: ...Telnet and the IP address of the Serial Server to be configured then click OK Figure 55 The Run dialogue box N No ot te e The Serial Server must be in RS 232 RS 422 or RS 485 mode before you can Telne...

Страница 37: ...c 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Pk Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www b...

Страница 38: ...e 9 pin D type male DB 9M DTE software selectable as RS 232 422 or 485 ESP902 Two 9 pin D type male DB 9M DTE Port 1 software selectable as RS 232 422 or 485 Port 2 RS232 only DC Power Ultra miniature...

Страница 39: ...ort 1 Baud Rate 9600 Data Stop 8 1 Parity None Flow Control None TCP UDP Protocol ESP901 serial port TCP ESP902 Ports 1 2 TCP Serial timeout 0 seconds TCP alive timeout 0 minutes Connection Mode Serve...

Страница 40: ...k Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com RS 232 Straight through Cable Connections In the RS 232 mode the Serial Server s ports are configured as DTEs like a comp...

Страница 41: ...Connections RS 232 Connections 74 Appendix A Manual Documentation Number ESP901 902_4105m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb...

Страница 42: ...lines are outputs and RXD lines are inputs Connect the Serial Server TXDB line to the RXDB line of the serial device and the Serial Server TXDA to the RXDA of the serial device If Flow Control is set...

Страница 43: ...Loopback Connections for RS 422 The RS 485 Connections are half duplex either Receive or Transmit so another half duplex device must be used to check operation Figure 69 RS 422 Connection with No Flo...

Страница 44: ...standard which defines the Data B line as positive relative to Data A during a Mark state before enabling the transmitter and after transmitting before tri stating If an RS 485 device does not respond...

Страница 45: ...used Blue 4 5 Not used White Blue 5 6 RX Orange 6 7 Not used White Brown 7 8 Not used Brown 8 Figure 72 Pin out for a Standard Ethernet Cable Network Connections 82 Appendix D Manual Documentation Num...

Страница 46: ...il orders bb elec com Fax 815 433 5109 Technical Support e mail support bb elec com Fax 815 433 5104 European Headquarters B B Electronics Ltd Westlink Commercial Park Oranmore Co Galway Ireland Phone...

Отзывы: