ESP904 Configuration
Step 1:
Open the
ESP Manager
software. It will automatically search for
any reachable (ESP90x)
Serial Servers
. A list of all
Serial Servers
connected to the LAN will appear in the
Serial Server List
window.
Step 2:
Double click the first ESP904 port on the list (4000) to bring up the
Server Properties
configuration screen.
Figure 2. The Server Properties Window
Step 3:
Change the
Server Properties
as required.
Enable
DHCP
to allow the ESP904 to generate its own IP
address
OR
Obtain appropriate static
IP
,
Netmask
and
Gateway
addresses
from your Network Administrator (recommended)
Set the
Console Mode
property to RS-232 to match the serial
device connected to the ESP904 serial port 1.
Set
Baud Rate
,
Data/Parity/Stop
, and
Flow Control
to match
the configuration of the serial device connected to the ESP904
serial port
Step 4:
When the parameters have been set, click
Update
. Following the
prompts in the dialogue boxes,
Restart
the Serial Server and
Search all reachable servers
again.
Step 5:
Re-enter
Server Properties
to verify the changes have taken effect,
or to view/change the configuration of other ports. Each port must
be configured separately.