background image

  

Hardware 

Overview 

Manual Documentation Number:  PES1A/PESV1A-4905m 

7

 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – 

www.bb-elec.com 

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – 

www.bb-europe.com 

Ethernet Port Connector 

The 

Ethernet Port

 connector is a standard RJ-45 receptacle that allows the 

serial server to be connected to an Ethernet network. It also carries Power 
over Ethernet (PoE) based on the IEEE 802.3af standard.  

On the PES1A/ PESV1A two indicator LEDs are built into the RJ-45 
connector. 

 

Serial Port Connector 

The 

Serial Port Connector

 is a DB-9 male connector (configured as a DTE) 

supporting RS-232 serial communications including TD, RD, TRS, CTS, 
DTR, DCD, DSR and GND signal lines.  Use a standard serial cable if 
connecting to a DCE; use a null modem (crossover) cable if connecting to a 
DTE. 

Refer to Appendices D, E and F for connection pin-outs. 

Power Connector 

Power is supplied to the PES1A/PESV1A by PoE (Power over Ethernet) via 
the RJ-45 Ethernet receptacle. Power over Ethernet may be delivered via un-
used pairs in the CAT-5 cable, or via a simplexed power technique. Both 
options are supported by the PES1A and PESV1A. PoE power consumption 
for the PES1A and PESV1A are rated Class 3. 

Refer to Appendix E for Ethernet connection pin-outs and additional information 
on PoE. 

Output Power Connector (PESV1A only) 

The output power connector (on the PESV1A only) is a two position 
removable terminal block that provides a DC power supply voltage output 
(derived from the PoE input power) in three selectable ranges: 5 VDC, 9 
VDC and 12 VDC. Maximum output power is 4 watts.  

 

Figure 5. 

Side View of the PESV1A 

 Hardware 

Overview 

Manual Documentation Number: PES1A/PESV1A-4905m  

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – 

www.bb-elec.com 

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – 

www.bb-europe.com 

Connecting the Hardware 

Typically, the PES1A/PESV1A is connected to a network via a hub, switch 
or router using standard CAT-5 cable. Power must be supplied to the 
converter via the CAT-5 cable using Power over Ethernet. Configuration is 
accomplished over the network, or via a direct connection (see below) using 
the Web Configuration and Management Interface 

Power over Ethernet (PoE) 

Power is supplied to your PES1A/PESV1A from PoE power source 
equipment (PSE), which must be installed within 100 meters of the 
converter. PSEs may be endspan or midspan devices. Endspan PSE devices 
may be switches or hubs with integrated PoE capability. Midspan PSE 
devices are dedicated, inline devices that are installed between your network 
switch and the PES1A/PESV1A.  

For more information on PoE see Appendix C. 

Serial Device

PC

PC

PES1A
or
PESV1A

Serial Cable

* Must be w ithin 100 ft  of the PES1A/PESV1A

Endspan PoE
Switch or Hub*

 

Figure 6. 

Connection using Endspan Power Source 

Содержание PESV1A

Страница 1: ...91 792445 www bb europe com M Mi in ni i P PO OE E E Et th he er rn ne et t t to o R RS S 2 23 32 2 C Co on nv ve er rt te er rs s M Mo od de el ls s P PE ES S1 1A A P PE ES SV V1 1A A Manual Documen...

Страница 2: ...dquarters B B Electronics Mfg Co Inc 707 Dayton Road Ottawa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 Website www bb elec com Sales e mail orders bb elec com Fax 815 433 5109 Technical...

Страница 3: ...ncluding photography recording or any information storage and retrieval system without written consent Information in this manual is subject to change without notice and does not represent a commitmen...

Страница 4: ...DDRESS 13 USING THE DISCOVERY SOFTWARE 13 ii Manual Documentation Number PES1A PESV1A 4905m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb...

Страница 5: ...l COM Port using RealPort 36 Removing a Virtual COM Port using RealPort 36 Updating RealPort 37 APPENDIX A DEFAULT CONFIGURATION SETTINGS 39 APPENDIX B PRODUCT SPECIFICATIONS 41 APPENDIX C DIMENSIONAL...

Страница 6: ...reland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 10 100 Mbps auto detecting operation IEEE 802 3af Power over Ethernet compatible Web Configuration and Management user interface Email event...

Страница 7: ...the PES1A PESV1A via a command line interface Modem Emulation Mode allows you to configure the serial port to operate as if it is a modem For legacy applications where a serial device is set up to com...

Страница 8: ...B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 7924...

Страница 9: ...PoE Output Power Connector PESV1A only The output power connector on the PESV1A only is a two position removable terminal block that provides a DC power supply voltage output derived from the PoE inp...

Страница 10: ...r typically is configured over the network connection using standard browser software It also could be connected directly to a PC network adapter To do so an Ethernet crossover cable is required Also...

Страница 11: ...discovery software on your CD finder exe to get the IP address for your PES1A PESV1A 5 Login In a web browser on your PC type in the IP address and access the Web Configuration and Management Interfac...

Страница 12: ...al IP address of your PES1A PESV1A start the finder exe utility included on the included CD Figure 9 Discovery Utility Dialog 3 The finder exe utility scans the network for devices and then lists each...

Страница 13: ...ssword after you have access the interface for the first time To change usernames and passwords and to add and configure new users see Managing Users and Permissions in Chapter 6 When the username and...

Страница 14: ...ce 18 Manual Documentation Number PES1A PESV1A 4905m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink...

Страница 15: ...uration and Management Interface 20 Manual Documentation Number PES1A PESV1A 4905m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com...

Страница 16: ...ber associated with its serial port After selecting UDP Sockets click Apply to return to the Serial Port Configuration page Select the TCP Server Settings as required by your application Using the Web...

Страница 17: ...allows you to set these parameters When the RealPort profile is selected the serial port settings will be directed by the PC applications using the virtual COM port Using the Web Configuration and Ma...

Страница 18: ...ec com To Send alarms based on serial data pattern matching select that option and type a character string into the text box provided Alarm Destinations Alarm Destinations allows you to specify where...

Страница 19: ...nics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353...

Страница 20: ...ion and Management Interface provides information about the current operational state of the PES1A PESV1A Serial Ports The Serial Port Management page displays information on Port number Description P...

Страница 21: ...o the PES1A PESV1A Caution When updating the firmware check the support site and release notes for more information to determine if the PES1A PESV1A must update the POST before updating the firmware F...

Страница 22: ...rk page displays statistics related to IP TCP UDP and ICMP protocol activities Figure 18 Network Information Page Using Administrative Features 34 Manual Documentation Number PES1A PESV1A 4905m B B El...

Страница 23: ...e Profile for the port If it is not RealPort click Port 1 4 On the page that appears click Change Profile 5 On the Select Port Profile page select RealPort then click Apply Using RealPort 36 Manual Do...

Страница 24: ...k Finish Windows 98 ME NT 4 0 1 Follow the readme txt included with each O S on the CD no setup exe available Updating RealPort Windows 2000 XP 1 Locate the RealPort driver software on the CD you rece...

Страница 25: ...Co on nf fi ig gu ur ra at ti io on n S Se et tt ti in ng gs s Server Name PES1A PESV1A Username root Password dbps DHCP Enabled Baud Rate 9600 Data Stop 8 1 Parity None Flow Control None TCP UDP Prot...

Страница 26: ...t Standards Supported IEEE 802 3 10 100 Mbps auto detecting 10BaseT 100BaseTX IEEE 802 3af Power over Ethernet compatibility for both data and spare pair lines Protocols Supported TCP UDP DHCP SNMP SS...

Страница 27: ...n na al l D Di ia ag gr ra am ms s Figure 19 Dimensional Diagram of the PES1A Figure 20 Dimensional Diagram of the PESV1A 2 000cm 9 800cm 3 327cm 4 204cm Power Over Ethernet to RS 232 Converter Model...

Страница 28: ...Pin Signal RS 232 DTE 1 Carrier Detect DCD In 2 Receive Data RXD In 3 Transmit Data TXD Out 4 Data Terminal Ready DTR Out 5 Signal Ground GND 6 Data Set Ready DSR In 7 Request To Send RTS Out 8 Clear...

Страница 29: ...or an Ethernet Cable showing PoE RJ 45 Pin Signal Wire Color PoE Alternative A PoE Alternative B 1 TX White Green Negative 2 TX Green Negative 3 RX White Orange Positive 4 Not used Blue Positive 5 Not...

Страница 30: ...ositive DC voltage simplexed to pins 3 and 6 Negative voltage is applied to pins 1 and 2 The powered device PD derives the power from these lines Alternative B carries power over spare wire pairs in t...

Страница 31: ...40 707Dayton Road Ottawa IL 61350 USA Model Numbers ESR901WB Description 1 Port 802 11b Wireless Serial Server Type Light industrial ITE equipment Application of Council Directive 89 336 EEC Standards...

Отзывы: