10/100 Mbps auto-detecting operation 

 

IEEE 802.3af (Power over Ethernet) compatible 

 

Web Configuration and Management user interface 

 

Email event notification 

 

Communication Modes 

PES1A/PESV1A  Ethernet  to  RS-232  converters 

allow  you  to  connect 

serial devices over a LAN or WAN. Serial devices no longer are limited to a 
physical connection to the PC COM port. They can be installed anywhere on 
the  LAN  using  TCP/IP  or  UDP/IP  communications.  This  allows  traditional 
Windows PC software access to serial devices anywhere on the LAN/WAN 
network.  

Direct IP 

Direct  IP  Mode

  allows  applications  using  TCP/IP  or  UDP/IP  socket 

programs  to  communicate  with  the  asynchronous  serial  ports  on  the  serial 
server.  In  this  mode  the  PES1A/PESV1A  is  configured  as  a  TCP  or  UDP 
server. The socket program running on the PC establishes a communication 
connection. The data is sent directly to and from the serial port on the server.  

TCP  Server  Mode 

allows  network  devices  to  initiate  a  TCP  connection  to 

the serial device connected to the serial port on the PES1A/PESV1A. This is 
also referred to as reverse telnet. 

UDP Server Mode 

allows network devices to initiate a UDP connection to 

the  serial  device  attached  to  the  serial  port  of  the  PES1A/PESV1A.  When 
using UDP protocol the PES1A/PESV1A can be configured to broadcast data 
to and receive data from multiple IP addresses.  

Virtual COM Port 

Virtual  COM  Port 

mode  (also  called  RealPort,  or  com  port  redirection)

 

allows  you  to  map  a  COM  port  on  your  PC  to  the  serial  port  on  your 
PES1A/PESV1A.  Using  the  RealPort  software

 

(included  with  the 

PES1A/PESV1A)  you  create  virtual  COM  ports  on  your  PC.  When  your 
application  sends  data  to  this  port,  RealPort  redirects  the  data  across  the 
network  to  serial  device  connected  to  the  PES1A/PESV1A  serial  port.  The 
network is transparent to the user application and the serial device connected 
to the PES1A/PESV1A.  

Содержание PES1A

Страница 1: ...0 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com M Mi in ni i P PO OE E E Et...

Страница 2: ...12m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91...

Страница 3: ...dquarters B B Electronics Mfg Co Inc 707 Dayton Road Ottawa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 Website www bb elec com Sales e mail orders bb elec com Fax 815 433 5109 Technical...

Страница 4: ......

Страница 5: ...ncluding photography recording or any information storage and retrieval system without written consent Information in this manual is subject to change without notice and does not represent a commitmen...

Страница 6: ......

Страница 7: ...PACKAGE CHECKLIST 5 INDICATORS SWITCHES AND CONNECTORS 6 Link Integrity LED Yellow 6 Network Activity LED 6 Reset Switch 6 Voltage Output Selector Switch PESV1A only 6 Ethernet Port Connector 7 Seria...

Страница 8: ...ile Settings 18 Basic Serial Settings 23 Advanced Serial Settings 24 CONFIGURING ALARMS AND NOTIFICATION 24 Alarm Notification Settings 24 Alarm Conditions 24 Alarm Destinations 25 CHAPTER 6 MANAGING...

Страница 9: ...91 792445 www bb europe com CHAPTER 8 USING REALPORT 35 Configuring the IP Address 35 Configuring the Serial Port for RealPort 35 Adding a Virtual COM Port using RealPort 36 Removing a Virtual COM Por...

Страница 10: ...m iv B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 9...

Страница 11: ...point of sale warehousing and banking equipment directly into Ethernet networks Both models feature Power over Ethernet PoE operation and the PESV1A provides a switch selectable voltage output to pow...

Страница 12: ...al server In this mode the PES1A PESV1A is configured as a TCP or UDP server The socket program running on the PC establishes a communication connection The data is sent directly to and from the seria...

Страница 13: ...lowing communications profiles Terminal Mode allows you to connect a PC running terminal software to the PES1A PESV1A serial port and communicate with the PES1A PESV1A via a command line interface Mod...

Страница 14: ...SV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph...

Страница 15: ...er rv vi ie ew w Package Checklist PES1A PESV1A PoE Ethernet to RS 232 Converters are shipped with the following items included The PES1A or PESV1A module A printed version of this user manual A prin...

Страница 16: ...the network Network Activity LED When the green LED located on the Ethernet jack is flashing it indicates data is being sent across the network Figure 4 LED Indicators on the PES1A Reset Switch The R...

Страница 17: ...D RD TRS CTS DTR DCD DSR and GND signal lines Use a standard serial cable if connecting to a DCE use a null modem crossover cable if connecting to a DTE Refer to Appendices D E and F for connection pi...

Страница 18: ...iguration is accomplished over the network or via a direct connection see below using the Web Configuration and Management Interface Power over Ethernet PoE Power is supplied to your PES1A PESV1A from...

Страница 19: ...he PES1A PESV1A Midspan PoE Power Source Switch or Hub Figure 7 Connection using Midspan Power Source Configuration Connections Your PES1A PESV1A converter typically is configured over the network con...

Страница 20: ...PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland...

Страница 21: ...this manual Quick Start guide 2 Set up the Hardware Connect your PC to the network Connect the PES1A PESV1A serial port to your serial device Use a serial cable if it is DCE null modem cable if it is...

Страница 22: ...port TCP Server UDP server Serial Bridge etc Configure the serial port settings for the selected Port Profile E g In TCP Sockets select client or server TCP port numbers etc Also configure baud rate d...

Страница 23: ...IP address using static IP addressing if necessary Your PES1A PESV1A comes from the factory configured to obtain an IP address dynamically or failing that to generate its own IP address using the APIP...

Страница 24: ...g the discovery software or you can open the Web Configuration and Management Interface and do it there See Configuring Network Settings later in the next chapter 1 To change the IP address of the PES...

Страница 25: ...face To login open your browser type the IP address of your PES1A PESV1A converter into the address bar and press Enter The Login page will appear 2 Enter your Username and Password then click Login T...

Страница 26: ...he Configuration and Management homepage Clicking Help on any page of the Configuration and Management Interface opens topics specific to that page After logging in if there is no activity for a perio...

Страница 27: ...ddress to itself using the Automatic Private IP Addressing APIPA protocol You can re configure the PES1A PESV1A for static IP address by selecting Use the following IP address and assign the IP addres...

Страница 28: ...ts parity stop bits You will have to configure these parameters to set up your system for the type of operation required and to match the parameters of the serial device to which the PES1A PESV1A is c...

Страница 29: ...e PES1A PESV1A you create a virtual COM port on the PC When your application sends data to this port RealPort redirects the data across the network to the PES1A PESV1A The PES1A PESV1A passes the data...

Страница 30: ...his is also referred to as reverse telnet Network devices initiating connections must be configured with the IP address of the PES1A PESV1A and the TCP port number associated with its serial port Afte...

Страница 31: ...ect UDP Sockets to implement Direct IP Mode using UDP protocol When using UDP Sockets your converter can be configured as a UDP server or UDP client UDP Server Settings If your PES1A PESV1A is configu...

Страница 32: ...P Server Settings UDP Client Settings If your PES1A PESV1A is configured as a UDP client you can automatically distribute serial data from you PES1A PESV1A to many devices at the same time This is som...

Страница 33: ...s set up to communicate through a modem the serial device can be connected to the PES1A PESV1A and communication occurs over the network The PES1A PESV1A emulates modem responses to and from the seria...

Страница 34: ...e current alarm settings and allows you to configure them It contains two sections Alarm Notification Settings and Alarm Conditions Note In the PES1A PESV1A GPIO lines are permanently configured as RS...

Страница 35: ...the condition of some RS 232 hardware handshake lines For assistance in implementing this feature contact B B Electronics Technical Support at 815 433 511 or support bb elec com To Send alarms based...

Страница 36: ...ation Number PES1A PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranm...

Страница 37: ...PES1A PESV1A the SNMP Contact person a text description of the Location of the PES1A PESV1A and the Device ID number Simple Network Management Protocol SNMP Settings The SNMP Settings page allows you...

Страница 38: ...other users and configure the specific rights of each Non administrators can also set up new users access and permissions if they have permission but a user cannot set another user s permission level...

Страница 39: ...anted to the user See the online help for more information on these choices Managing Serial Ports and Connections The Management section of the Web Configuration and Management Interface provides info...

Страница 40: ...ES1A PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ire...

Страница 41: ...htm or index html file will automatically load that page upon logging into the PES1A PESV1A Backup Restore The Backup Restore page allows you to backup the current configuration settings on your PES1A...

Страница 42: ...bb europe com System Information The System Information page displays information about your PES1A PESV1A General Model MAC Address Firmware Version Boot Version POST Version CPU Utilization Up Time...

Страница 43: ...350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Figure 17 Serial Port Dia...

Страница 44: ...0 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Reboot The...

Страница 45: ...rts configuring your serial port with the RealPort profile you must use RealPort to configure those ports on your PC Once you have configured a new virtual COM VCOM port using RealPort application sof...

Страница 46: ...dialog appears listing the IP Address MAC Address and Model of all devices on the network To identify your PES1A PESV1A compare the MAC address listed with the MAC address on the label on your PES1A P...

Страница 47: ...at appears select the COM port number to be assigned to the PES1A PESV1A Click Next A progress screen will appear 7 When the process is complete click Finish Windows 98 ME NT 4 0 1 Follow the readme t...

Страница 48: ...PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland...

Страница 49: ...Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com A Ap pp pe en nd di ix x A A D De ef fa au ul lt t C Co on nf fi ig gu ur ra at ti io on n S...

Страница 50: ...r PES1A PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway...

Страница 51: ...nts Class 3 Power over Ethernet PoE Power Consumption Class 3 device for PoE configuration Power Output PESV1A only 5 9 or 12VDC 4W maximum slide switch selectable Connector is pluggable two position...

Страница 52: ...s Direct IP TCP or UDP Sockets Virtual COM Port RealPort Paired Mode serial bridge serial tunneling Terminal Modem Emulation Custom Configuration Method Uses any web browser via built in web server Cu...

Страница 53: ...Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com A Ap pp pe en nd di ix x C C D Di im me en ns si io on na al l D Di ia ag gr ra am ms s Figure 19...

Страница 54: ...1A PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Irela...

Страница 55: ...Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com A Ap pp pe en nd di ix x D D R RS S 2 23 32 2 C Co on nn ne ec ct ti io on ns s DB 9M Pin Signal RS 232 DTE 1 Carrier Detect DCD In...

Страница 56: ...A PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Irelan...

Страница 57: ...353 91 792444 Fax 353 91 792445 www bb europe com A Ap pp pe en nd di ix x E E N Ne et tw wo or rk k C Co on nn ne ec ct ti io on ns s Figure 22 Pin out for an Ethernet Cable showing PoE RJ 45 Pin Si...

Страница 58: ...A PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Irelan...

Страница 59: ...ng method for delivering power to the end device Power is carried on the same conductors as data Cabling for standard 10BaseT and 100BaseTX Ethernet typically Category 5 cable with RJ 45 connectors us...

Страница 60: ...Power Source Data Pair Data Pair Powered End Station 6 2 Negative Positive Negative Positive 7 8 4 5 7 8 4 5 1 1 3 3 Figure 24 Power over Ethernet Alternative B DECLARATION OF CONFORMITY Manufacturer...

Отзывы: