8
straight-through cable. If the connected Modbus device is
configured as a DTE, use a null modem cable.
Always check the interface specifications of the Modbus device to
determine whether it is a DTE or DCE before connecting.
The
MES1B
is connected to its Modbus device via the RS-422/485
terminal block. In RS-422/485 four-wire mode a cable containing
two pairs and a ground/shield is used. In RS-485 two-wire mode a
cable containing one pair and a ground/shield is used.
Power is supplied to the converter via the power supply terminal
block.
Typically, the MES1A/B is connected to the network via a hub
switch or router using standard straight-through CAT-5 cable. (If
you are connecting the MES1A/B directly to a PC’s network
interface a crossover Ethernet cable is required.)
Figure 8.
MES1A Connections