B&B Electronics iCaddy DCDSS1 Скачать руководство пользователя страница 12

Documentation Number DCDSS11702 Manual

Appendix A

9

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

Chapter 4: Specifications

Serial Ports
Modem Port:

RS-232, DTE, DB9 male connector

Data Rates:

600 – 115,200 baud, N-8-1 only

ISP:

User configurable for primary and
secondary (fallback) ISP accounts
Supports standard (AT command set)
modems

Local Port:

RS-232, DTE, DB9 male connector

Data Rates:

300 – 115.2 kbps

Data Bits:

5, 6, 7, or 8

Stop Bit:

1, 1.5, or 2

Parity:

None, even, or odd

Serial Data Buffer Size:

60 Kbytes

Triggers for Data Delivery
Time Based Trigger:

Configurable from once per minute to
once per month

Buffer Trigger:

Configurable 10 – 80% of buffer capacity

Digital Input:

Active high or low, 0 – 5V input,
5 ms min. pulse width
Removable terminal block connection

Data/Fault Notification:

E-mail or pager

Data Delivery:

FTP or e-mail attachment (MIME)

Timestamp:

User enabled, new data time-stamped
after 1 minute of idle

Number of Polling Strings:

10 user definable, each with
independent transmit schedule

Max. Polling Strings Length: 35 bytes per string
Email Addresses Supported: 10
Pager Supported:

1

FTP Addresses Supported: 2
Mounting:

Desktop or panel mount using provided
holes in case flange

Power Requirements:

10–30 VDC, 650 mW maximum
Removable terminal block connection

Indicators:

3 LED’s for power/status, modem, and
local serial port activity

Size:

6.5 x 4.9 x 1.5 in (16.5 x 11.2 x 3.5 cm)

Shipping Weight:

0.9 lb (0.4 kg)

Software (included):

CD for Windows 95/98/ME/2000/XP/NT 4.0

Содержание iCaddy DCDSS1

Страница 1: ...and imported parts by International Headquarters B B Electronics Mfg Co Inc 707 Dayton Road P O Box 1040 Ottawa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 Home Page www bb elec com Order...

Страница 2: ...to change without notice and does not represent a commitment on the part of B B Electronics B B Electronics shall not be liable for incidental or consequential damages resulting from the furnishing pe...

Страница 3: ...apter 2 Operation 2 Data Storage 2 Data Buffer and Time Stamping 2 Polling Strings 2 Data Delivery Triggers 2 Time Based Trigger 2 Buffer Based Trigger 3 Digital Input Trigger 3 Data Delivery Methods...

Страница 4: ...reached or based on a digital alarm input It replaces local or long distance phone calls with an automated Internet connection to your Internet Service Provider Instead of calling out to remote sites...

Страница 5: ...5 bytes in length Each polling string is individually configured and sent out of the local serial port on a time based trigger In the PC setup software fields are chosen to schedule the polling interv...

Страница 6: ...ata Delivery Methods Data and error logs can be emailed using a MIME attachment or sent using FTP Additionally notifications can be configured to allow email or pager notification that data has been d...

Страница 7: ...600 to 115 2 kbps A 60 byte initialization string can be programmed to be sent to the modem before the ISP number is dialed This port is configured as a DTE device a standard serial modem cable shoul...

Страница 8: ...defined ID The user defined ID can be up to 32 characters long Some sample subject lines are listed below data buffer SWfieldPump 1 error time StorageTank4 notification digital WestEntrance FTP Setup...

Страница 9: ...DCDSS1 now features a remote buffer retrieval mode This feature allows the user to manually the gather data or error stored in the buffer at any time remotely This mode uses modem to modem communicati...

Страница 10: ...emove power from iCaddy at any time during these steps Doing so will erase the data and error buffers 2 Connect an available COM port to the modem side of iCaddy using a null modem cable 3 Open the em...

Страница 11: ...This will set the DCDSS1 to configure mode Use the provided null modem setup cable to connect the local serial port of the DCDSS1 to any available serial port of your computer and then run the iCaddy...

Страница 12: ...rom once per minute to once per month Buffer Trigger Configurable 10 80 of buffer capacity Digital Input Active high or low 0 5V input 5 ms min pulse width Removable terminal block connection Data Fau...

Страница 13: ...792445 Appendix A Declaration of Conformity DECLARATION OF CONFORMITY Manufacturer s Name B B Electronics Manufacturing Company Manufacturer s Address P O Box 1040 707 Dayton Road Ottawa IL 61350 USA...

Отзывы: