Server Properties Configuration 

Manual Documentation Number: ESP904-0504 

Chapter 5 

31 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – 

www.bb-elec.com

 

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – 

www.bb-europe.com

 

C

C

h

h

a

a

p

p

t

t

e

e

r

r

 

 

5

5

:

:

 

 

C

C

O

O

N

N

F

F

I

I

G

G

U

U

R

R

I

I

N

N

G

G

 

 

T

T

H

H

E

E

 

 

E

E

S

S

P

P

9

9

0

0

4

4

 

 

S

S

E

E

R

R

V

V

E

E

R

R

 

 

P

P

R

R

O

O

P

P

E

E

R

R

T

T

I

I

E

E

S

S

 

 

 

 

The VLINX Serial Server can be configured using any of four different user 
interfaces: the 

ESP Manager

 software, the 

Web Server

Console Mode

 or 

Telnet

. The 

Server Properties

 described in this chapter can be changed from 

any of these user interfaces.  

Description of the Server Properties 

Server Name  

A new Server Name of up to 16 characters can be entered. If more than one 
ESP901 or ESP902 or ESP904 Servers are connected on the LAN it is 
recommended that a new name be assigned to each. When the ESP Manager 
finds ESP Servers on the LAN it displays the server name and IP Address 
allowing the user to distinguish between ESP servers. 

Password 

Entering a password activates a security feature on the serial server. Once a 
password is entered it will be required to access the menu and make changes.  

DHCP 

DHCP servers are a part of numerous LAN management systems. The DHCP 
field provides two choices: 

Disable

 and 

Enable

. Disable is the normal, or 

default, setting. When enabled, the ESP904 will send a DHCP request to the 
DHCP server, which will assign a dynamic IP address, net mask, and 
gateway to the ESP904. If a DHCP server is not available on the network the 
ESP904 will time out after 10 seconds and the default values will remain. 

N

N

o

o

t

t

e

e

:

:

 

 

 

 

A dynamic address assigned by the DHCP server may change if the ESP904 

loses the Ethernet connection or power is removed. The host (client) 
communication software requests a connection to the specific IP address of the 
serial server. If the DHCP reassigns a different IP address the software will not 

be able to communicate with the hardware. Therefore, using a static IP address 
is recommended. 

 

Server Properties Configuration

 

32 

Chapter 5 

Manual Documentation Number: ESP904-0504 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – 

www.bb-elec.com

 

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – 

www.bb-europe.com

 

 

IP Address 

Software or hardware attempting to access the ESP904 server via the 
network must know the 

IP Address

 of the server. A static IP address is 

retained and remains the same each time the server is powered up or 
starts/restarts. The default IP address of the ESP904 server is printed on a 
label on the bottom cover of the ESP904. Entering an appropriate address in 
the IP Address field and updating the server will change the server’s IP 
address. The network administrator can assign/establish the static address or 
group of addresses to be used. 

The IP Address of the ESP904 server can be confirmed using the DOS Ping 
command. 

N

N

o

o

t

t

e

e

:

:

 

 

 

 

To use 

Ping

 to check for communications: 

- Access a DOS window (in XP click on 

Start

, then 

Run

- At run prompt enter: 

CMD

 

- In the DOS window enter: 

Ping xxx.xxx.xxx.xxx

 (IP address for the ESP904 

to be confirmed) 
 - The command will return the Ping results indicating 4 replies  

Netmask 

The default LAN netmask is configured for a Class C address. The user may 
change this. Default is 255.255.255.0 

Gateway 

The Gateway IP address allows users to access the serial server from outside 
the LAN.  

MAC Address  

The MAC address is fixed and cannot be changed. It is assigned in the 
factory. Every Ethernet device manufactured has it own unique MAC 
address.  

Link Status 

Link status automatically displays the type of Ethernet connection. It will 
either display 10BaseT or 100BaseTX in full duplex or half duplex. This will 
depend on the LAN, switches, hubs used in the LAN topology.  

Содержание ESP904

Страница 1: ...om B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com M Mo od de el ls s E ES SP P9 90 04 4 E ES SP P9 90 04 4E E Q Qu ua ad d P...

Страница 2: ...tronics Mfg Co Inc 707 Dayton Road P O Box 1040 Ottawa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 Website www bb elec com Sales e mail orders bb elec com Fax 815 433 5109 Technical Suppo...

Страница 3: ...SOFTWARE INSTALLATION 19 ii Table of Contents Manual Documentation Number ESP904 0504 B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec...

Страница 4: ...32 MODE 57 RS 232 Straight through Cable Connections 58 RS 232 Crossover null modem Cable Connections 58 RS 232 Straight through DB 9 to DB 25 Conversion Connections 59 RS 232 Crossover DB 9 to DB 25...

Страница 5: ...igure 27 The Device Manager Window 40 Figure 28 The VLINX ESP COM3 Properties Window 41 Figure 29 The ESP Manager Window 43 Figure 30 The vcomui Dialogue Box 44 Figure 31 The Control Panel Window 45 F...

Страница 6: ...ram and an RS 232 crossover cable Telnet also can be used to access the setup configuration menu Virtual COM Driver Software for Windows installs a virtual COM port viewable in the Windows Device Mana...

Страница 7: ...l connection provides a reliable communications connection in Virtual COM Port Mode or with Paired Connection Mode This feature restores the connection if communications are temporarily lost at either...

Страница 8: ...Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe co...

Страница 9: ...stlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com ESP904 Technical Data Hardware and Included Accessories ESP904 Serial Server module Power Supply 12...

Страница 10: ...IP Address 192 168 0 1 Net Mask 255 255 255 0 Gateway 192 168 0 254 MAC Address Fixed see bottom label Port 1 Console Mode Ports 2 3 4 RS 232 Baud Rate 9600 Data Parity Stop 8 N 1 Flow Control None TC...

Страница 11: ...ec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com ESP904 Connections Indicators and Reset Switch The ESP904 has Seven ind...

Страница 12: ...Fax 353 91 792445 www bb europe com Serial Port Operational Modes Using the ESP Manager or the Console Mode Configuration Menu each serial port can independently be configured as RS 232 Mode RS422 Mod...

Страница 13: ...l must be set to RTS CTS during configuration N No ot te e Refer to Appendix B RS 422 connection pin outs RS 485 Mode RS 485 Mode supports the transmit TX and receive RX signal channels using 2 wire h...

Страница 14: ...Data TXD Out TXDB Data B 4 Data Terminal Ready DTR Out TXDA Data A 5 Signal Ground GND GND GND 6 Data Set Ready DSR In CTSA 7 Request To Send RTS Out CTSB 8 Clear To Send CTS In RTSB 9 Ring Indicator...

Страница 15: ...n Step 1a Inserting the VLINX CD in the CD ROM should automatically launch the Install Shield Wizard Manual Installation Step 1b To manually start the software installation select the Start button on...

Страница 16: ...ger software Start Programs B B Electronics VLINX ESP Servers VLINX ESP Manager Step 6 If the ESP904 is not already connected to the network or to the Ethernet port on the computer connect it and then...

Страница 17: ...re Hardware Setup Step 1 Connect the ESP904 to the LAN or to a computer Ethernet port Figure 17 Ethernet Connection via a LAN Using ESP Manager 24 Chapter 4 Manual Documentation Number ESP904 0504 B B...

Страница 18: ...50 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com The Virtual COM List conta...

Страница 19: ...l Documentation Number ESP904 0504 B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Or...

Страница 20: ...next property Tab Shift to move back to previous property Arrows to move between properties or change values or contents of the current property Enter to select update or cancel Using ESP Manager 30 C...

Страница 21: ...tware requests a connection to the specific IP address of the serial server If the DHCP reassigns a different IP address the software will not be able to communicate with the hardware Therefore using...

Страница 22: ...n Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe...

Страница 23: ...or arrow keys to move the cursor to the option position and then press Enter Save stores the configuration data to ESP904 flash memory and resets it Default restores the editing configuration data to...

Страница 24: ...software to open a connection with the serial port located anywhere on the LAN WAN When using the virtual COM port the ESP904 is configured as a TCP or UDP Server Virtual COM Port Installation Step 1...

Страница 25: ...etting is None RTS CTS can be selected if used by the application program and serial hardware The ESP Server must be set to match Installing Virtual COM Port 40 Chapter 6 Manual Documentation Number E...

Страница 26: ...ect the Configuration or Port Settings tab This screen allows the settings to be changed if necessary Click on Cancel to keep the existing settings Step 5 Click on OK to change the settings Use Refres...

Страница 27: ...indows select VLINX ESP Manager from the Programs list Start Programs B B Electronics VLINX ESP Servers VLINX ESP Manager Step 2 In the ESP Manager window select the Virtual COM List tab Highlight the...

Страница 28: ...expand Figure 32 The Device Manager Window Removing a Virtual COM Port 46 Chapter 7 Manual Documentation Number ESP904 0504 B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815...

Страница 29: ...click on the server to be upgraded The Server Properties window will appear Step 2 If using a direct connection to serial port 1 to upload the firmware to the ESP904 set the baud rate to 115 2k for t...

Страница 30: ...4 Fax 353 91 792445 www bb europe com Step 10 Upgrade progress will be shown until the Upgrade finished message is shown Select OK Figure 35 Upgrading in Progress Upgrade Mode 50 Chapter 8 Manual Docu...

Страница 31: ...904 Port 1 via an RS 232 crossover cable Step 3 In the HyperTerminal Port Settings window set o Baud rate 9600 o Data bits 8 o Parity None o Stop bits 1 o Flow control None Click OK Step 4 To view the...

Страница 32: ...write the settings to the server Step 7 To view the changes press the space bar The screen will reappear Using Console Mode 54 Chapter 9 Manual Documentation Number ESP904 0504 B B Electronics Mfg Co...

Страница 33: ...the window and press Enter The following window will appear Figure 39 The Web Server Page Using the Web Server 56 Chapter 10 Manual Documentation Number ESP904 0504 B B Electronics Mfg Co Inc 707 Day...

Страница 34: ...792444 Fax 353 91 792445 www bb europe com RS 232 Straight through Cable Connections In the RS 232 mode the ESP904 s ports are configured as DTEs like a computer If the device connected to the ESP904...

Страница 35: ...null modem Cable RS 232 Connections 60 Appendix A Manual Documentation Number ESP904 0504 B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb...

Страница 36: ...l In the RS 422 mode TXD lines are outputs and RXD lines are inputs Connect the ESP904 TXDB line to the RXDB line of the serial device and the ESP904 TXDA to the RXDA of the serial device If Flow Cont...

Страница 37: ...Loopback Connections for RS 422 The RS 485 Connections are half duplex either Receive or Transmit so another half duplex device must be used to check operation Figure 50 RS 422 Connection with No Flo...

Страница 38: ...85 standard which defines the Data B line as positive relative to Data A during a Mark state before enabling the transmitter and after transmitting before tri stating If an RS 485 device does not resp...

Страница 39: ...used Blue 4 5 Not used White Blue 5 6 RX Orange 6 7 Not used White Brown 7 8 Not used Brown 8 Figure 53 Pin out for a Standard Ethernet Cable Network Connections 68 Appendix D Manual Documentation Num...

Отзывы: