background image

EIR505 Series-5107qsg

    

 

 

International Headquarters: 

 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 

815-433-5100  Fax 433-5104    

www.bb-elec.com

    

[email protected]

   [email protected] 

 

European Headquarters:

   Westlink Commercial Park   Oranmore Co. Galway Ireland 

                                                                      +

353 91 792444   Fax +353 91 792445   

www.bb-europe

.com   [email protected]  [email protected]

 

 

 

Quick Start Guide 

 

Elinx Managed Ethernet Switch 

EIR505 Series  

 

Items Included 

1

2

 

Default Settings 

3

 

DIP Switch Settings 

4

 

LED Chart 

5

 

Hardware Installation 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

o

 

Ethernet Switch 

o

 

CD with Support Manual 

o

 

This Quick Start Guide 

o

 

Panel Mount Bracket 

 
 

 

o

 

IP Address: 192.168.16.1 

o

 

Subnet Mask: 255.255.255.0 

o

 

Gateway: 192.168.15.254 

o

 

User Name: root, Password: root 

 

 
 

 
 
 
 
 
 

 
 
 
 
 
 
 

 
 

 

 

 

o

 

Record the switch’s MAC Address in the space 
provided. The MAC Address is printed on the product 
label. Provide the MAC Address to your Network 
Administrator. The Network Administrator should 
provide an IP Address, Subnet Mask, and Gateway.
 

o

 

Select a mounting location and install with the attached 
DIN rail clip or included panel mount kit. 

o

 

Connect power to the switch 

o

 

12 to 48 VDC 

o

 

Redundant DC input is available with fault 
contacts. 

 
 

Pos 

Status  Description 
OFF 

Disable port 1 Alarm 

ON 

Enable port 1 Alarm  
(If port 1 link fails, the fault LED will light) 

OFF 

Disable port 2 Alarm 

ON 

Enable port 2 Alarm 
(If port 2 link fails, the fault LED will light) 

OFF 

Disable port 3 Alarm 

ON 

Enable port 3 Alarm 
(If port 3 link fails, the fault LED will light) 

OFF 

Disable port 4 Alarm 

ON 

Enable port 4 Alarm 
(If port 4 link fails, the fault LED will light) 

OFF 

Disable port 5 Alarm 

ON 

Enable port 5 Alarm 
(If port 5 link fails, the fault LED will light) 

OFF 

Disable the ring master function 

ON 

Enable the switch as the ring master 
in the redundant ring group. 

 
 
 
 

 

 

 

 

 

 

 

 

 

LED Status 

 

Meaning 

Green 

The switch is powered on 

Power 

Off 

The switch is powered off 

R.M. 

Green 

Ring Master (Master of a Redundant Ring) 

(Ring Master)  Off 

The switch is not a Ring Master 

Green 

Power Source 1 is available 

Power 1 

Off 

Power Source 1 is unavailable 

Green 

Power Source 2 is available 

Power 2 

Off 

Power Source 2 is unavailable 

Yellow 

Power Source Failure or Port Failure 

Fault 

Off Normal 

Operation 

Green 

The port is linked 

Blinking 

The port is receiving or transmitting packets 

Link/ACT 

Port 5 

Off  

No device attached 

Yellow 

Full Duplex Mode 

Blinking Data 

Collision 

FDX/COL 

Port 5 

Off 

Half Duplex Mode 

 

 

 

 

 

Отзывы: