(i.e. it is served by a shared medium LAN segment). This function
allows the P2P status of the link to be manipulated administratively.
True is P2P enabling. False is P2P disabling.
Admin Edge:
The port directly connected to end stations cannot create
a bridging loop. To configure the port as an edge port, set the port to
“
True
” status.
Admin Non Stp:
The port includes the STP mathematic calculation.
True
does not include the STP mathematic calculation.
False
includes
the STP mathematic calculation.
Click
Apply
[NOTE]
If the configuration is not saved, it will be lost when the switch
is powered off.
RSTP – Per Port Configuration interface