DSP-100 Enabler program must be used to configure the adapter. If the
Client Driver reports the desired adapter configuration, the installation
process is complete and the DSP-100 may be removed and/ or inserted from
the system as desired. On each insertion into the PCMCIA socket, the
DSP-100 will be automatically reconfigured according to the command line
options.
2.1.2 Command Line Options
The DSP-100 Client Driver accepts up to eight command line arguments from the user
to determine the configuration of theDSP-100. If any arguments are provided, the
Client Driver will attempt to configure any DSP-100s with the options specified in the
order they are entered on the command line. Each argument must be enclosed in
parenthesis and must be separated from other arguments by a
space
on the command
line. Within each argument, any or all of the following parameters may be specified
using a
comma (no spaces)
to separate each parameter:
B
address
specifies a the base I/O address of the DSP-100 in hexadecimal. This
address must reside on an even 8-byte boundary. If this option is omitted, a
base address will be assigned by Card and Socket Services.
I
irq
specifies the interrupt level (IRQ) of the DSP-100 in decimal.
irq
must be one
of the following values: 3, 4, 5, 7, 9, 10, 11, 12, 14, 15, or 0 if no IRQ is
desired. If this option is omitted, an interrupt level will be assigned by Card
and Socket Services.
S
socket
specifies which PCMCIA socket the DSP-100 must be inserted into for this
configuration argument to be used.
socket
must be in the range 0 - 15. If this
option is omitted, the configuration argument will apply to DSP-100s
inserted into any socket.
C
clock
specifies the multiple of the standard frequency for the UART clock. Valid
values for
clock
are 1 or 8. A value of 1 yields a clock frequency of 1.8432
MHz; a value of 8 yields 14.7456 MHz. If this option is omitted, the
standard clock frequency will be used.
2.1.2.1Example 1
DEVICE = C:\DSP-100\ DSP130CL.SYS
In example 1, no command line arguments are specified. The Client Driver will
configure a DSP-100 inserted into any socket with a base address and IRQ assigned by
Card and Socket Services.