Getting Started:

 

 

 

 

 
 

 

1

 

 

Open the Airbor

ne™

 Evaluation Kit packaging and locate the Install CD. 

 

2

 

 

Place the CD in the CD/DVD drive of the laptop or desktop you will be using to configure the Airborne

™ 

device. Follow the on screen directions for installation of the appropriate device software and 
documentation. 

 

 
 

3

 

Connect the Ethernet cable to the Ethernet port on the EVB and to an Ethernet port on the laptop or 
desktop system. 

 

Change the IP configuration of the laptop/desktop Ethernet interface to “Obtain an IP address 

automatically”.

 

4

 

 

Apply power to the Evaluation Kit. Move the Power switch (SW1) to the Power On position. 

 

5

 

The EVB will boot. Confirm that the POST LED is illuminated (Orange). This indicates the module is ready 
to be configured. 

If the POST LED is not illuminated check the power connections and reapply power (Make sure that  
SW1 is in the correct position). If the POST LED does not illuminate, contact B&B Electronics Technical  
Support.

 

Even though the module is ready to be configured, you may have to wait a minute for the 

module and laptop/desktop to fall back to 169.254.x.x IP address. 

 
 
 

 

6

 

Run the Airborne Management Center (AMC) application. This was installed during the CD installation 
and a menu item will be found in the Airborne folder located in the Programs directory of your 
system. When the application opens the following dialog will be displayed: 

 

Select Group Name: 

manuf 

and enter Group Password: 

dpac

 

 

 
 

7

 

The AMC will discover the EVB and show the following message: 

 

Press 

Yes 

 

 

 

8

 

The AMC will ask of the devices are factory default: 

 

Press 

Yes 

 

 

 

 

Содержание Airborne WLNN-EK-DP55 Series

Страница 1: ...ess mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer IC Socket Relay Connector Our parts cover such applications as commercial industrial and automotives areas We are looking forward to setting up business relationship with you and hope to provide you...

Страница 2: ...se contact B B Electronics Sales support directly at 888 948 2248 or support bb elec com What you will need To evaluate the unit you will need the following components and facilities EVB unit with included antenna attached Laptop or desktop system with an Ethernet port Power outlet for power supply 802 11b g n or 802 11a n network for testing the unit either AdHoc or Infrastructure Access Points m...

Страница 3: ...t the POST LED is illuminated Orange This indicates the module is ready to be configured If the POST LED is not illuminated check the power connections and reapply power Make sure that SW1 is in the correct position If the POST LED does not illuminate contact B B Electronics Technical Support Even though the module is ready to be configured you may have to wait a minute for the module and laptop d...

Страница 4: ...ver You can change the device functionality by selecting an appropriate personality committing the change and restarting the unit To change the personality 1 Select the Maintenance link in the top menu bar 2 Select the Change Module Personality link in the left hand menu 3 Select the appropriate device personality See Device Personality section 4 Press Commit 5 Press Restart The device will restar...

Страница 5: ... is set as a router Suitable for applications where there are multiple Ethernet clients on the Ethernet network Also supports dual UARTs debug port and 802 11a b g n ABDN ER DP55X ABDN ER IN501X WLNN ER DP55X Ethernet Client Bridge Ethernet bridge designed to connect wireless 802 11a b g n to an existing Ethernet port Suitable for applications where there is a single Ethernet client to be connecte...

Страница 6: ...ies The Change Module Personality page can be seen in Figure 1 After selecting the appropriate personality you must press the Commit button and Restart the module to save and apply the change Figure 1 Change Module Personality Setup Page 1 The web interface is context sensitive Not all of the fields will be visible without a context change ...

Страница 7: ... Dayton Road Ottawa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 Website www bb elec com European Headquarters B B Electronics Ltd Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792445 Website www bb europe com ...

Отзывы: