Figure 4 shows the jumper settings for RS-485 mode. 

 

Figure 4.  RS-485 Mode Jumper Settings 

RS-485 Pinouts 

 

The pinouts in RS-485 mode are the same as those listed in 

Table 7 for RS-422 mode.   

RS-485 Operation 

 

RS-485 mode requires that the driver be enabled and 

disabled as needed, allowing two or four-wire communications. To 
set up the 3PXCC1A Serial Card up for two wire mode you can 
simply jumper TD(A) to RD(A) (for your Data “-“) and TD(B) to RD(B) 
(for your Data “+”). Use the Signal Ground for your return path as 
the third wire in this configuration. For four wire mode, simply use all 
four data lines and signal ground for a return path.  

The 3PXCC card provides two methods of 

enabling/disabling the driver: automatic send data (SD) control and 
request to send (RTS) control. With automatic SD control, the driver 
is enabled when data is transmitted. It remains enabled for the 
transmission time of one character after data transfer is complete. 
The SD circuit automatically adjusts its timing to the baud rate of the 
data. With RTS control, software must set the RTS bit to a logic 1 to 
enable the driver and logic 0 to disable the driver. To select SD 
control, place jumpers JP1D and JP2D in the SD position (left). 
Place these jumpers in the RTS position (right) for RTS control. 

 

38  

Documentation 

No.3PXCC1x-2x-3903 

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 

B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 

 

The receiver can also be enabled and disabled, a useful 

feature in two-wire communications to prevent the transmitted data 
from "echoing back" on its own receiver. Jumpers JP1C and JP2C 
control this feature for Port 1 and Port 2. If these jumpers are placed 
in the RS-485 position, the "echo" is turned off. This is achieved by 
disabling the receiver when the driver is enabled.  Placing these 
jumpers in the RS-422 position will hold the receiver enabled at all 
times. More information on RS-485 communications can be found in 
B&B Electronics’ free RS-422/RS-485 Application Note. 

RS-422 and RS-485 Termination 

 A 

120

 termination resistor has been provided for the RS-

422/485 receivers. To enable the termination provided, place JP1E 
for Port 1 or JP2E for Port 2 in the Rt IN position (right). If you do not 
need to use termination, place the jumpers in the Rt OUT position 
(left). Termination should only be used when very long wiring runs 
are used with high baud rates. For example, with most cables which 
are 4000 feet or shorter and have baud rates at 19.2K baud or 
lower, termination is not required. Note that if the termination is 
enabled (IN), the biasing of the RS-485 network is altered and the 
value of the bias resistors will likely need to be changed somewhere 
on the network. More information on termination and biasing can be 
found in B&B Electronics’ free RS-422/RS-485 Application Note. 

High Speed Mode 

 

High data rates can be obtained with the 3PXCC cards by 

adjusting JP1G and JP2G. This multiplies the clock speed supplied 
to the UARTs by 4 times to 7.328MHz for ports 1 and 2 respectively, 
allowing data rates up to 460.8K baud in RS-422 and RS-485 
modes.  Note: RS-232 does not support these extended baud rates. 

 

To use the higher clock rate, place the jumper for the 

appropriate port in the *4 (left) position.  The jumpers are shipped 
from the factory in the standard clock (right) position. 

 

Note that serial software is not aware of the change in 

oscillator frequency. For example, in the 

×

4 position, setting the 

baud rate to 57.6K baud in software will result in a actual baud rate 
of 230.4K baud. It is important to note that increasing the baud rate 
may not increase actual throughput. In heavy multitasking cases or 
with a slow computer, the computer’s inability to respond to 
interrupts quickly enough will cause large idle spaces between 
characters. Increasing the baud rate to this point will not increase 
actual throughput. 

 

Содержание 3PXCC1A

Страница 1: ...ts on the card The model number of the card is printed on a sticker on the board This product designed and manufactured in Ottawa Illinois USA of domestic and imported parts by International Headquart...

Страница 2: ...ecking Windows 2000 for Available Address IRQ s 18 Adding Serial Port s in Windows 2000 22 Chapter 4 Address and IRQ Setting 29 Address Switch Setup 29 Interrupt Jumper Setup 32 Chapter 5 Communicatio...

Страница 3: ...CD DTR and RI Specifications Bus IBM PC ISA Bus Slot Requires 1 full length slot for complete IRQ selectability When installed in a short slot IRQ s 10 15 will not be available Dimensions 6 3 x 3 3 in...

Страница 4: ...for Available Address IRQ s in Chapter 3 for your operating system Refer to Chapter 4 Table 3 for frequently unused I O Addresses and IRQ s Write down the address and IRQ you select to use Do not phys...

Страница 5: ...lick on System Properties Left click on Device Manager Double click on Computer 6 Documentation No 3PXCC1x 2x 3903 B B Electronics Mfg Co 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax...

Страница 6: ...hich will be seen in the list You might have to start at COM3 or COM4 to begin addressing the ISA card If these addresses are used you may have to resort to the Frequently Unused Port Addresses found...

Страница 7: ...353 91 792445 Click Next Select Yes No for the device in the list Click Next 10 Documentation No 3PXCC1x 2x 3903 B B Electronics Mfg Co 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 81...

Страница 8: ...For now simply click Next Windows may ask for the Windows 95 98 disk CD to be inserted Finally click Finish 12 Documentation No 3PXCC1x 2x 3903 B B Electronics Mfg Co 707 Dayton Rd PO Box 1040 Ottawa...

Страница 9: ...Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 Click off check mark out of box Use automatic settings Select Basic Configuration 0007 or last one Select Input Output Range Click Change Se...

Страница 10: ...entation No 3PXCC1x 2x 3903 B B Electronics Mfg Co 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 B B Electronics Ltd Westlink Comm Pk Oranmore Galway Ireland Ph 353 91 792...

Страница 11: ...see a screen System Setting Change Click the button Restart Now to restart Windows NT 4 0 At this point you can shut down the system and physically install your B B Electronics Serial Card into an ava...

Страница 12: ...lick on View top of screen Click on Resources by type Double click on Input Output Find an unused address to set your B B Electronics serial card to Scroll through the list checking 03F8H 02F8H 03E8H...

Страница 13: ...Interrupt Request IRQ Here you need to find an unused IRQ to set your B B Electronics serial card to 22 Documentation No 3PXCC1x 2x 3903 B B Electronics Mfg Co 707 Dayton Rd PO Box 1040 Ottawa IL 613...

Страница 14: ...91 792444 Fax 353 91 792445 Click Next Click on Add Troubleshoot a device Click Next 24 Documentation No 3PXCC1x 2x 3903 B B Electronics Mfg Co 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 510...

Страница 15: ...26 Documentation No 3PXCC1x 2x 3903 B B Electronics Mfg Co 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 B B Electronics Ltd Westlink Comm Pk Oranmore Galway Ireland Ph 35...

Страница 16: ...ess Double click on the Interrupt Request to set the IRQ Select IRQ and Address that you want your port s configured at 28 Documentation No 3PXCC1x 2x 3903 B B Electronics Mfg Co 707 Dayton Rd PO Box...

Страница 17: ...ding all 16 bits of the ISA address bus Address settings in our ISA bus serial cards is set by DIP switches selecting bits 11 4 or jumpers B B Electronics 3PXCC cards are factory configured for COM1 I...

Страница 18: ...upt Jumper Setup The IRQ is a hardware Interrupt Request line in an ISA Bus expansion slot on a PC or AT compatible computer The 8 bit PC ISA slot has 8 interrupts the 16 bit slot has another 7 since...

Страница 19: ...mm Pk Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 Table 4 Standard IRQ Settings COM1 IRQ4 COM2 IRQ3 COM3 IRQ4 COM4 IRQ3 34 Documentation No 3PXCC1x 2x 3903 B B Electronics Mfg Co 707 Da...

Страница 20: ...0 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 B B Electronics Ltd Westlink Comm Pk Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 RS 422 Mode To configure a port for RS 422 mode 7 jum...

Страница 21: ...aced in the RS 485 position the echo is turned off This is achieved by disabling the receiver when the driver is enabled Placing these jumpers in the RS 422 position will hold the receiver enabled at...

Страница 22: ...Carrier Detect input 2 RD Receive Data input 3 TD Transmit Data output 4 DTR Data Terminal Ready output 5 GND Signal Ground 6 DSR Data Set Ready input 7 RTS Request to Send output 8 CTS Clear to Send...

Страница 23: ...ly set 3 Try another software package for troubleshooting Download SimpTerm DOS Terminal Emulator or Comtest Windows Terminal Emulator from B B Electronics web site SimpTerm and Comtest are shareware...

Страница 24: ...ayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 B B Electronics Ltd Westlink Comm Pk Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 Any eight byte space not used by o...

Страница 25: ...turer s Address P O Box 1040 707 Dayton Road Ottawa IL 61350 USA Model Numbers 3PXCC1A 3PXCC1B 3PXCC2A 3PXCC2B Description RS 232 Serial Card Type Light industrial ITE equipment Application of Council...

Отзывы: