4
2IQEC2/43798 Manual
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 433-5105
Table 1. Address Switches
1st Digit
2nd Digit
Switch
Position
7
6
5
4
3
2
1
Bus
Connection
SA10
SA9
SA8
SA7
SA6
SA5
SA4
Decimal
Weight
1024
512
256
128
64
32
16
Hex Weight
400
200
100
80
40
20
10
To set the address of the 2IQEC2/4 card at some common
locations, follow the switch settings shown in Table 2.
Table 2. Frequently Unused Port Addresses
Base
Hex
Address
Binary
Equivalent
Switch
Settings
MSB
LSB
7654321
I/O Space
Description
200
1000000000
0100000
game port
300
1100000000
0110000
prototype
310
1100010000
0110001
prototype
380
1110000000
0111000
SDLC
3A0
1110100000
0111010
bisync com
To install at another address, follow the procedure below.
1.
Select the address. Using an I/O port usage table (one is
included in Appendix A) select an unused hex address
space. Note that the card occupies 16 bytes of I/O space.
Use caution when selecting a port address. It is very
important that nothing else is installed at the selected
address.
2.
Convert the hex address to its binary equivalent.
3.
Throw away the 4 least significant bits.
4.
The remaining 7 digits represent the switch address. 1's
represent an OFF switch. 0's represent an ON switch.