Documentation Number 232MSS2-0108 Manual
19
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445
Command Line Method
This method enables the user to select any Smart Switch port
through the command line. To specify a Smart Switch port through
the command line, you would type
SSTSR
followed by the
X
command symbol and the letter of the port.
Example:
To change to Smart Switch port '"C" you would type
SSTSR XC
at the Dos prompt and press the
ENTER
key.
Before a Smart Switch port is changed, a check is made to
determine if the port is busy transmitting. If the port is busy the
STSR will generate a tone to notify you that the port is busy and that
a port change cannot be made.
CAUTION: If the software package you are using for
transmission is running at a fast baud rate (57600), the
SSTSR may not detect the Smart Switch port as busy and the
transmission could be interrupted.
The SSTSR does not detect when the Smart Switch port is
receiving data. Therefore, if data is being received, the Smart Switch